Literature DB >> 25077555

Comparing four non-invasive methods to determine the ventilatory anaerobic threshold during cardiopulmonary exercise testing in children with congenital heart or lung disease.

Naomi C A Visschers1, Erik H Hulzebos1, Marco van Brussel1, Tim Takken1,2.   

Abstract

BACKGROUND: The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate.
OBJECTIVE: To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT.
METHODS: CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included.
RESULTS: No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs.
CONCLUSION: The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA.
© 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  anaerobic threshold; child; congenitally corrected transposition of the great arteries; cystic fibrosis; exercise test

Mesh:

Year:  2014        PMID: 25077555     DOI: 10.1111/cpf.12183

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  2 in total

1.  Determination of ideal target exercise heart rate for cardiac patients suitable for rehabilitation.

Authors:  Shih Jia Janice Tan; John Carson Allen; Swee Yaw Tan
Journal:  Clin Cardiol       Date:  2017-07-06       Impact factor: 2.882

2.  Wheelchair Shuttle Test for Assessing Aerobic Fitness in Youth With Spina Bifida: Validity and Reliability.

Authors:  Manon A T Bloemen; Janke F de Groot; Frank J G Backx; Joyce Benner; Cas L J J Kruitwagen; Tim Takken
Journal:  Phys Ther       Date:  2017-10-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.