Naomi C A Visschers1, Erik H Hulzebos1, Marco van Brussel1, Tim Takken1,2. 1. Child Development & Exercise Centre, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands. 2. Partner of Shared Utrecht Pediatric Exercise Research (SUPER) Lab, Utrecht, The Netherlands.
Abstract
BACKGROUND: The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. OBJECTIVE: To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. METHODS: CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. RESULTS: No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. CONCLUSION: The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA.
BACKGROUND: The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. OBJECTIVE: To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. METHODS: CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. RESULTS: No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. CONCLUSION: The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA.