Literature DB >> 25074544

A fluorogenic heterogeneous immunoassay for cardiac muscle troponin cTnI on a digital microfluidic device.

Maria-Nefeli Tsaloglou1, Adrian Jacobs, Hywel Morgan.   

Abstract

We describe a fluorogenic two-site noncompetitive heterogeneous immunoassay with magnetic beads on a low-voltage digital microfluidic platform using closed electrowetting-on-dielectric (EWOD). All the steps of an enzyme-linked immunosorbent assay (ELISA) were performed on the device using 9H-(1, 3-dichloro-9, 9-dimethylacridin-2-one-7-yl) phosphate as the fluorogenic substrate for the enzyme alkaline phosphatase. The performance of the system was demonstrated with cardiac marker Troponin I (cTnI) as a model analyte in phosphate-buffered saline samples. cTnI was detected within the diagnostically relevant range with a limit of detection of 2.0 ng/mL (CV = 6.47 %). Washing of magnetic beads was achieved by movement through a narrow region of buffer bridging one drop to another with minimal fluid transfer. More than 90 % of the unbound reagents were removed after five washes. Further experiments testing human blood serum on the same platform demonstrated a sample-to-answer time at ∼18.5 min detecting 6.79 ng/mL cTnI.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25074544     DOI: 10.1007/s00216-014-7997-z

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Rapid and Sensitive Detection of Cardiac Troponin I for Point-of-Care Tests Based on Red Fluorescent Microspheres.

Authors:  Yanxue Cai; Keren Kang; Qianru Li; Yu Wang; Xiaowei He
Journal:  Molecules       Date:  2018-05-07       Impact factor: 4.411

Review 2.  Opto-Microfluidic Immunosensors: From Colorimetric to Plasmonic.

Authors:  Jie-Long He; Da-Shin Wang; Shih-Kang Fan
Journal:  Micromachines (Basel)       Date:  2016-02-15       Impact factor: 2.891

3.  Horseradish peroxidase-triggered direct in situ fluorescent immunoassay platform for sensing cardiac troponin I and SARS-CoV-2 nucleocapsid protein in serum.

Authors:  Jinhua Liu; Guotong Ruan; Wenlin Ma; Yujie Sun; Haidong Yu; Zhihui Xu; Changmin Yu; Hai Li; Cheng-Wu Zhang; Lin Li
Journal:  Biosens Bioelectron       Date:  2021-11-21       Impact factor: 12.545

4.  Modeling, simulation, and optimization of electrowetting-on-dielectric (EWOD) devices.

Authors:  Qiuxu Wei; Wenliang Yao; Le Gu; Bolin Fan; Yongjia Gao; Li Yang; Yingying Zhao; Chuncheng Che
Journal:  Biomicrofluidics       Date:  2021-02-01       Impact factor: 2.800