Abstract

Detection and removal of sentinel lymph nodes (SLN) is important in the diagnosis and treatment of cancer. The SLN is the first regional lymph node draining the primary tumor, and if the cancer has spread, it is most likely to find metastases in the SLN. In this study, we have for the first time been able to image the very same contrast agent, superparamagnetic iron oxide nanoparticles (SPIO-NPs), in rat SLNs by using both our frequency- and phase-gated magnetomotive ultrasound (MMUS) algorithm and conventional magnetic resonance imaging (MRI); MMUS post mortem, MRI in vivo. For both higher NP-concentration and smaller NPs, we found that the MMUS data showed a larger magnetomotive displacement (1.56 ± 0.43 and 1.94 ± 0.54 times larger, respectively) and that the MR-images were affected to a higher degree. The MMUS displacement also increased with lower excitation frequency (1.95 ± 0.64 times larger for 5 Hz compared with 15 Hz) and higher excitation voltage (2.95 ± 1.44 times larger for 30 V compared with 10 V). The results show that MMUS has potential to be used as bedside guidance during SLN surgery, imaging the same particles that were used in prior staging with other imaging techniques.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25073135     DOI: 10.1109/TUFFC.2014.3034

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  6 in total

1.  Magnetomotive Optical Coherence Elastography for Magnetic Hyperthermia Dosimetry Based on Dynamic Tissue Biomechanics.

Authors:  Pin-Chieh Huang; Paritosh Pande; Adeel Ahmad; Marina Marjanovic; Darold R Spillman; Boris Odintsov; Stephen A Boppart
Journal:  IEEE J Sel Top Quantum Electron       Date:  2015-12-17       Impact factor: 4.544

2.  Inversion of displacement fields to quantify the magnetic particle distribution in homogeneous elastic media from magnetomotive ultrasound.

Authors:  Diwash Thapa; Benjamin E Levy; Daniel L Marks; Amy L Oldenburg
Journal:  Phys Med Biol       Date:  2019-06-20       Impact factor: 3.609

3.  Blind Source Separation-Based Motion Detector for Imaging Super-Paramagnetic Iron Oxide (SPIO) Particles in Magnetomotive Ultrasound Imaging.

Authors:  Md Murad Hossain; Benjamin E Levy; Diwash Thapa; Amy L Oldenburg; Caterina M Gallippi
Journal:  IEEE Trans Med Imaging       Date:  2018-06-15       Impact factor: 10.048

4.  Single Magnetic Particle Motion in Magnetomotive Ultrasound: An Analytical Model and Experimental Validation.

Authors:  Benjamin E Levy; Amy L Oldenburg
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-07-26       Impact factor: 3.267

5.  Combined Magnetomotive ultrasound, PET/CT, and MR imaging of 68Ga-labelled superparamagnetic iron oxide nanoparticles in rat sentinel lymph nodes in vivo.

Authors:  Maria Evertsson; Pontus Kjellman; Magnus Cinthio; Roger Andersson; Thuy A Tran; Rene In't Zandt; Gustav Grafström; Hanna Toftevall; Sarah Fredriksson; Christian Ingvar; Sven-Erik Strand; Tomas Jansson
Journal:  Sci Rep       Date:  2017-07-06       Impact factor: 4.379

Review 6.  Magnetic mediators for ultrasound theranostics.

Authors:  Arkadiusz Józefczak; Katarzyna Kaczmarek; Rafał Bielas
Journal:  Theranostics       Date:  2021-11-02       Impact factor: 11.556