Literature DB >> 25072552

Modified HeartMate II driveline externalization technique significantly decreases incidence of infection and improves long-term survival.

Ajeet Singh1, Mark J Russo, Tracy B Valeroso, Allen S Anderson, Jonathan D Rich, Valluvan Jeevanandam, Shahab A Akhter.   

Abstract

Driveline (DL) infection has been a major source of morbidity and mortality following HeartMate II left ventricular assist device (LVAD) implant, despite a significantly lower incidence compared with pulsatile flow devices. The purpose of this study was to compare the incidence of DL infection using two different externalization techniques. Between July 1, 2008, and October 15, 2011, 125 consecutive patients underwent HeartMate II LVAD implant at a single institution. Patients that underwent implant in 2008-2009 (n = 45) had the velour portion of the DL externalized (Velour group) and those that were implanted in 2010-2011 (n = 80) had only the silicone portion externalized (Silicone group). Kaplan-Meier analysis with log-rank test was used to compare actuarial DL infection-free survival and a composite of death and DL infection-free survival. There were 20/45 (44.4%) DL infections in the Velour group compared with 7/80 (8.8%) in the Silicone group. Driveline infection-free survival was significantly better for the Silicone versus Velour group as was the composite end-point of death and infection-free survival (p < 0.001). Externalization of only the silicone portion of the DL led to a dramatic reduction in infections and significantly improved survival after implant. This represents an opportunity to decrease the incidence of this important cause of morbidity and mortality after LVAD implant.

Entities:  

Mesh:

Year:  2014        PMID: 25072552     DOI: 10.1097/MAT.0000000000000121

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  9 in total

Review 1.  Artificial hearts-recent progress: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2017-06-15       Impact factor: 1.731

2.  Left Ventricular Assist Device Infections: A Systematic Review.

Authors:  John C O'Horo; Omar M Abu Saleh; John M Stulak; Mark P Wilhelm; Larry M Baddour; M Rizwan Sohail
Journal:  ASAIO J       Date:  2018 May/Jun       Impact factor: 2.872

Review 3.  A review of infections in patients with left ventricular assist devices: prevention, diagnosis and management.

Authors:  Barry H Trachtenberg; Andrea Cordero-Reyes; Barbara Elias; Matthias Loebe
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Jan-Mar

Review 4.  Non-patient factors associated with infections in LVAD recipients: A scoping review.

Authors:  Supriya Shore; Michael J Pienta; Tessa M F Watt; Gardner Yost; Whitney A Townsend; Lourdes Cabrera; Michael D Fetters; Carol Chenoweth; Keith D Aaronson; Francis D Pagani; Donald S Likosky
Journal:  J Heart Lung Transplant       Date:  2021-10-22       Impact factor: 13.569

5.  Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices-5-year follow-up.

Authors:  Leonhard Wert; Jasmin S Hanke; Günes Dogan; Marcel Ricklefs; Felix Fleißner; Anamika Chatterjee; Christina Feldmann; Axel Haverich; Jan D Schmitto
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

Review 6.  Minimally-invasive LVAD Implantation: State of the Art.

Authors:  Jasmin S Hanke; Sebastian V Rojas; Murat Avsar; Axel Haverich; Jan D Schmitto
Journal:  Curr Cardiol Rev       Date:  2015

7.  An in vitro Reconstructed Human Skin Equivalent Model to Study the Role of Skin Integration Around Percutaneous Devices Against Bacterial Infection.

Authors:  Eleonore C L Bolle; Anthony D Verderosa; Rabeb Dhouib; Tony J Parker; John F Fraser; Tim R Dargaville; Makrina Totsika
Journal:  Front Microbiol       Date:  2020-05-14       Impact factor: 5.640

Review 8.  Ventricular Assist Device-Specific Infections.

Authors:  Yue Qu; Anton Y Peleg; David McGiffin
Journal:  J Clin Med       Date:  2021-01-25       Impact factor: 4.241

9.  Driveline Features as Risk Factor for Infection in Left Ventricular Assist Devices: Meta-Analysis and Experimental Tests.

Authors:  Melanie Kranzl; Martin Stoiber; Anne-Kristin Schaefer; Julia Riebandt; Dominik Wiedemann; Christiane Marko; Günther Laufer; Daniel Zimpfer; Heinrich Schima; Thomas Schlöglhofer
Journal:  Front Cardiovasc Med       Date:  2021-12-16
  9 in total