Literature DB >> 25071965

Non-contact small animal fluorescence imaging system for simultaneous multi-directional angular-dependent data acquisition.

Jong Hwan Lee1, Hyun Keol Kim2, Chandhanarat Chandhanayingyong3, Francis Young-In Lee3, Andreas H Hielscher4.   

Abstract

We present a novel non-contact small animal fluorescent molecular tomography (FMT) imaging system. At the heart of the system is a new mirror-based imaging head that was designed to provide 360-degree measurement data from an entire animal surface in one step. This imaging head consists of two conical mirrors, which considerably reduce multiple back reflections between the animal and mirror surfaces. These back reflections are common in existing mirror-based imaging heads and tend to degrade the quality of raw measurement data. In addition, the introduction of a novel ray-transfer operator allows for the inclusion of the angular dependent data in the image reconstruction process, which results in higher image resolution. We describe in detail the system design and implementation of the hardware components as well as the transport-theory-based image reconstruction algorithm. Using numerical simulations, measurements on a well-defined phantom and a live animal, we evaluate the system performance and show the advantages of our approach.

Keywords:  (170.0110) Imaging systems; (170.6280) Spectroscopy, fluorescence and luminescence; (170.6960) Tomography

Year:  2014        PMID: 25071965      PMCID: PMC4102365          DOI: 10.1364/BOE.5.002301

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  18 in total

1.  Fluorescence molecular tomography resolves protease activity in vivo.

Authors:  Vasilis Ntziachristos; Ching-Hsuan Tung; Christoph Bremer; Ralph Weissleder
Journal:  Nat Med       Date:  2002-06-24       Impact factor: 53.440

2.  A submillimeter resolution fluorescence molecular imaging system for small animal imaging.

Authors:  Edward E Graves; Jorge Ripoll; Ralph Weissleder; Vasilis Ntziachristos
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

Review 3.  A multi-view time-domain non-contact diffuse optical tomography scanner with dual wavelength detection for intrinsic and fluorescence small animal imaging.

Authors:  Eric Lapointe; Julien Pichette; Yves Bérubé-Lauzière
Journal:  Rev Sci Instrum       Date:  2012-06       Impact factor: 1.523

4.  Imaging performance of a hybrid x-ray computed tomography-fluorescence molecular tomography system using priors.

Authors:  Angelique Ale; Ralf B Schulz; Athanasios Sarantopoulos; Vasilis Ntziachristos
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization.

Authors:  Hao Gao; Hongkai Zhao
Journal:  Opt Express       Date:  2010-02-01       Impact factor: 3.894

6.  Combined diffuse optical tomography (DOT) and MRI system for cancer imaging in small animals.

Authors:  Gultekin Gulsen; Ozlem Birgul; Mehmet Burcin Unlu; Roshanak Shafiiha; Orhan Nalcioglu
Journal:  Technol Cancer Res Treat       Date:  2006-08

7.  Monitoring early tumor response to drug therapy with diffuse optical tomography.

Authors:  Molly L Flexman; Fotios Vlachos; Hyun Keol Kim; Shashank R Sirsi; Jianzhong Huang; Sonia L Hernandez; Tessa B Johung; Jeffrey W Gander; Ari R Reichstein; Brooke S Lampl; Antai Wang; Mark A Borden; Darrell J Yamashiro; Jessica J Kandel; Andreas H Hielscher
Journal:  J Biomed Opt       Date:  2012-01       Impact factor: 3.170

8.  Quantitative fluorescence tomography using a combined tri-modality FT/DOT/XCT system.

Authors:  Yuting Lin; William C Barber; Jan S Iwanczyk; Werner Roeck; Orhan Nalcioglu; Gultekin Gulsen
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

9.  Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice.

Authors:  Sachin Patwardhan; Sharon Bloch; Samuel Achilefu; Joseph Culver
Journal:  Opt Express       Date:  2005-04-04       Impact factor: 3.894

10.  A three-dimensional multispectral fluorescence optical tomography imaging system for small animals based on a conical mirror design.

Authors:  Changqing Li; Gregory S Mitchell; Joyita Dutta; Sangtae Ahn; Richard M Leahy; Simon R Cherry
Journal:  Opt Express       Date:  2009-04-27       Impact factor: 3.894

View more
  2 in total

1.  Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

Authors:  Reheman Baikejiang; Yue Zhao; Brett Z Fite; Katherine W Ferrara; Changqing Li
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

2.  Non-contact dynamic diffuse optical tomography imaging system for evaluating lower extremity vasculature.

Authors:  J W Hoi; H K Kim; C J Fong; L Zweck; A H Hielscher
Journal:  Biomed Opt Express       Date:  2018-10-19       Impact factor: 3.732

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.