Literature DB >> 25071951

Probability method for Cerenkov luminescence tomography based on conformance error minimization.

Xintao Ding1, Kun Wang2, Biao Jie3, Yonglong Luo4, Zhenhua Hu2, Jie Tian5.   

Abstract

Cerenkov luminescence tomography (CLT) was developed to reconstruct a three-dimensional (3D) distribution of radioactive probes inside a living animal. Reconstruction methods are generally performed within a unique framework by searching for the optimum solution. However, the ill-posed aspect of the inverse problem usually results in the reconstruction being non-robust. In addition, the reconstructed result may not match reality since the difference between the highest and lowest uptakes of the resulting radiotracers may be considerably large, therefore the biological significance is lost. In this paper, based on the minimization of a conformance error, a probability method is proposed that consists of qualitative and quantitative modules. The proposed method first pinpoints the organ that contains the light source. Next, we developed a 0-1 linear optimization subject to a space constraint to model the CLT inverse problem, which was transformed into a forward problem by employing a region growing method to solve the optimization. After running through all of the elements used to grow the sources, a source sequence was obtained. Finally, the probability of each discrete node being the light source inside the organ was reconstructed. One numerical study and two in vivo experiments were conducted to verify the performance of the proposed algorithm, and comparisons were carried out using the hp-finite element method (hp-FEM). The results suggested that our proposed probability method was more robust and reasonable than hp-FEM.

Keywords:  (100.3190) Inverse problems; (110.6960) Tomography; (170.3010) Image reconstruction techniques; (170.3660) Light propagation in tissues; (170.3880) Medical and biological imaging; (170.6280) Spectroscopy, fluorescence and luminescence

Year:  2014        PMID: 25071951      PMCID: PMC4102351          DOI: 10.1364/BOE.5.002091

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  37 in total

1.  Uniqueness theorems in bioluminescence tomography.

Authors:  Ge Wang; Yi Li; Ming Jiang
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

2.  Experimental Cerenkov luminescence tomography of the mouse model with SPECT imaging validation.

Authors:  Zhenhua Hu; Jimin Liang; Weidong Yang; Weiwei Fan; Congye Li; Xiaowei Ma; Xueli Chen; Xiaopeng Ma; Xiangsi Li; Xiaochao Qu; Jing Wang; Feng Cao; Jie Tian
Journal:  Opt Express       Date:  2010-11-22       Impact factor: 3.894

Review 3.  Looking and listening to light: the evolution of whole-body photonic imaging.

Authors:  Vasilis Ntziachristos; Jorge Ripoll; Lihong V Wang; Ralph Weissleder
Journal:  Nat Biotechnol       Date:  2005-03       Impact factor: 54.908

4.  A definition of molecular imaging.

Authors:  David A Mankoff
Journal:  J Nucl Med       Date:  2007-06       Impact factor: 10.057

5.  A finite-element-based reconstruction method for 3D fluorescence tomography.

Authors:  Alexander Cong; Ge Wang
Journal:  Opt Express       Date:  2005-11-28       Impact factor: 3.894

6.  Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization.

Authors:  Hao Gao; Hongkai Zhao
Journal:  Opt Express       Date:  2010-02-01       Impact factor: 3.894

7.  Multimodal imaging with (18)F-FDG PET and Cerenkov luminescence imaging after MLN4924 treatment in a human lymphoma xenograft model.

Authors:  Robbie Robertson; Melissa Saylor Germanos; Mark G Manfredi; Peter G Smith; Matthew D Silva
Journal:  J Nucl Med       Date:  2011-10-12       Impact factor: 10.057

8.  Oxygen tomography by Čerenkov-excited phosphorescence during external beam irradiation.

Authors:  Rongxiao Zhang; Scott C Davis; Jennifer-Lynn H Demers; Adam K Glaser; David J Gladstone; Tatiana V Esipova; Sergei A Vinogradov; Brian W Pogue
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

9.  Three-dimensional noninvasive monitoring iodine-131 uptake in the thyroid using a modified Cerenkov luminescence tomography approach.

Authors:  Zhenhua Hu; Xiaowei Ma; Xiaochao Qu; Weidong Yang; Jimin Liang; Jing Wang; Jie Tian
Journal:  PLoS One       Date:  2012-05-22       Impact factor: 3.240

10.  Quantitative modeling of Cerenkov light production efficiency from medical radionuclides.

Authors:  Bradley J Beattie; Daniel L J Thorek; Charles R Schmidtlein; Keith S Pentlow; John L Humm; Andreas H Hielscher
Journal:  PLoS One       Date:  2012-02-20       Impact factor: 3.240

View more
  4 in total

1.  Enhanced Cerenkov luminescence tomography analysis based on Y2O3:Eu3+ rare earth oxide nanoparticles.

Authors:  Yongheng Gao; Xiaowei Ma; Fei Kang; Weidong Yang; Yi Liu; Zhengjie Wang; Wenhui Ma; Zhe Wang; Guoquan Li; Xu Cao; Jing Wang
Journal:  Biomed Opt Express       Date:  2018-11-08       Impact factor: 3.732

2.  Attention mechanism-based locally connected network for accurate and stable reconstruction in Cerenkov luminescence tomography.

Authors:  Xiaoning Zhang; Meishan Cai; Lishuang Guo; Zeyu Zhang; Biluo Shen; Xiaojun Zhang; Zhenhua Hu; Jie Tian
Journal:  Biomed Opt Express       Date:  2021-11-18       Impact factor: 3.732

3.  Reconstruction Method for Optical Tomography Based on the Linearized Bregman Iteration with Sparse Regularization.

Authors:  Chengcai Leng; Dongdong Yu; Shuang Zhang; Yu An; Yifang Hu
Journal:  Comput Math Methods Med       Date:  2015-09-01       Impact factor: 2.238

4.  Image Restoration for Fluorescence Planar Imaging with Diffusion Model.

Authors:  Xuanxuan Zhang; Yuzhu Gong; Yang Li; Xu Cao; Shouping Zhu
Journal:  Biomed Res Int       Date:  2017-11-27       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.