Literature DB >> 25070792

Free-hand placement of occipital condyle screws: a cadaveric study.

Mohamed Ali El-Gaidi1, Ehab Mohamed Eissa, Ehab A A El-Shaarawy.   

Abstract

PURPOSE: Cranio-vertebral junction fixation is challenging due to the complex topographical anatomy and the presence of important anatomical structures. There are several limitations to the traditional occipital squama fixation methods. The purpose of this work is to assess the safety and feasibility of a new optimum trajectory of occipital condyle (OC) screws for occipitocervical fixation via a free-hand technique.
METHODS: Eight different parameters of OC morphology were studied in fifty adult skulls. Free-hand placement of OC screws was performed in five cadavers using 3.5-mm titanium polyaxial screws and a 3-mm rod construct (C0-C1-C2). Postoperative computed tomography was performed to determine the success of the screw placement and their angulation, length and effect on hypoglossal canal volume.
RESULTS: The average length, width and height of the OC were 24.2 ± 3.6, 14.2 ± 1.9, and 10.7 ± 2 mm, respectively. The average medio-lateral, hypoglossal canal and atlanto-occipital joint angles were 38.8° medially ±5°, 7.4° rostrally ±1.9° and 23.4° caudally ±3.5°, respectively. The ten screws were successfully inserted using a free-hand technique with bicortical purchase. There was no vertebral artery injury or breach of the hypoglossal canal in any specimen. The average screw length was 22.2 ± 3.9 mm. The average medio-lateral angle was 30° medially ±6.7°. The average cranio-caudal angle was 4° caudally ±6.2°.
CONCLUSIONS: The free-hand technique of OC screw placement is a safe and viable option for occipitocervical fixation and may be a preferred alternative in selected cases. However, further studies are needed to compare its safety and reliability to other more established methods.

Entities:  

Mesh:

Year:  2014        PMID: 25070792     DOI: 10.1007/s00586-014-3488-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  22 in total

1.  Craniocervical fixation with occipital condyle screws: biomechanical analysis of a novel technique.

Authors:  Juan S Uribe; Edwin Ramos; A Samy Youssef; Nick Levine; Alexander W L Turner; Wesley M Johnson; Fernando L Vale
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

2.  Posterior occipitocervical fusion. A preliminary report of a new technique.

Authors:  D Grob; J Dvorak; M Panjabi; M Froehlich; J Hayek
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

3.  Feasibility of occipital condyle screw placement for occipitocervical fixation: a cadaveric study and description of a novel technique.

Authors:  Juan S Uribe; Edwin Ramos; Fernando Vale
Journal:  J Spinal Disord Tech       Date:  2008-12

4.  Cadaveric study for placement of occipital condyle screws: technique and effects on surrounding anatomic structures.

Authors:  Frank La Marca; Geoffrey Zubay; Thomas Morrison; Dean Karahalios
Journal:  J Neurosurg Spine       Date:  2008-10

5.  Computed tomographic morphometric analysis of the pediatric occipital condyle for occipital condyle screw placement.

Authors:  Sheng-Lei Lin; Dong-Dong Xia; Wei Chen; Yao Li; Zhong-Hai Shen; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Spine (Phila Pa 1976)       Date:  2014-02-01       Impact factor: 3.468

6.  Microsurgical anatomy of the transcondylar, supracondylar, and paracondylar extensions of the far-lateral approach.

Authors:  H T Wen; A L Rhoton; T Katsuta; E de Oliveira
Journal:  J Neurosurg       Date:  1997-10       Impact factor: 5.115

7.  Posterior occipitocervical (C0-3) fusion using polyaxial occipital condyle to cervical spine screw and rod fixation: a radiographic and cadaveric analysis.

Authors:  Bruce M Frankel; Michael Hanley; Alex Vandergrift; Timothy Monroe; Steven Morgan; Zoran Rumboldt
Journal:  J Neurosurg Spine       Date:  2010-05

8.  Microsurgical anatomy of the region of the foramen magnum.

Authors:  E de Oliveira; A L Rhoton; D Peace
Journal:  Surg Neurol       Date:  1985-09

9.  A retrospective study of congenital osseous anomalies at the craniocervical junction treated by occipitocervical plate-rod systems.

Authors:  Xianjun Ding; Kuniyoshi Abumi; Manabu Ito; Hideki Sudo; Masahiko Takahata; Ken Nagahama; Akira Iwata
Journal:  Eur Spine J       Date:  2012-05-01       Impact factor: 3.134

10.  Occipital screws in occipitocervical fusion and their relation to the venous sinuses: an anatomic and radiographic study.

Authors:  Y Nadim; J Lu; F F Sabry; N Ebraheim
Journal:  Orthopedics       Date:  2000-07       Impact factor: 1.390

View more
  3 in total

1.  Anatomical feasibility for safe occipital condyle screw fixation.

Authors:  Ho Jin Lee; Doo Yong Choi; Myoung Hoon Shin; Jong Tae Kim; Il Sup Kim; Jae Taek Hong
Journal:  Eur Spine J       Date:  2016-01-30       Impact factor: 3.134

2.  Morphometric Trajectory Analysis for Occipital Condyle Screws.

Authors:  Yu-Kun Du; Si-Yuan Li; Wen-Jiu Yang; Xiang-Yang Wang; Yi-Fang Bi; Jun Dong; Hui Huang; Feng Gao; Gui-Zhi Li; Hua-Wei Wei; Jian-Kun Yang; Yong-Ming Xi
Journal:  Orthop Surg       Date:  2020-06-03       Impact factor: 2.071

3.  Morphometric Evaluation of Occipital Condyles: Defining Optimal Trajectories and Safe Screw Lengths for Occipital Condyle-Based Occipitocervical Fixation in Indian Population.

Authors:  Aju Bosco; Prakash Venugopal; Ajoy Prasad Shetty; Rajasekaran Shanmuganathan; Rishi Mugesh Kanna
Journal:  Asian Spine J       Date:  2018-04-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.