Literature DB >> 25069651

Principal component model for maternal ECG extraction in fetal QRS detection.

Jukka A Lipponen1, Mika P Tarvainen.   

Abstract

Fetal cardiac monitoring using noninvasive abdominal leads can provide important information on fetal well-being. However, extraction of fetal electrocardiogram (fECG) from abdominal signals is often problematic because of the higher amplitude maternal ECG (mECG). The aim of this study was to introduce a principal component model for removing the maternal ECG from abdominal signals. The proposed method removes mECG waveforms with high accuracy even though abdominal movements cause morphological deviation to mECG complexes. The method can be used for single or multi-lead measurements. The proposed method was tested using 175 1 min long abdominal measurements with fetal QRS annotation markers acquired from a fetal scalp electrode. Using the presented mECG removing algorithm and matched filtering based fQRS detector, 95% sensitivity for fQRS detection and 4.84 ms RMS error for fetal RR-interval estimation were acquired.

Entities:  

Mesh:

Year:  2014        PMID: 25069651     DOI: 10.1088/0967-3334/35/8/1637

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Non-invasive fetal ECG analysis.

Authors:  Gari D Clifford; Ikaro Silva; Joachim Behar; George B Moody
Journal:  Physiol Meas       Date:  2014-07-29       Impact factor: 2.833

2.  A Combined Independent Source Separation and Quality Index Optimization Method for Fetal ECG Extraction from Abdominal Maternal Leads.

Authors:  Lucia Billeci; Maurizio Varanini
Journal:  Sensors (Basel)       Date:  2017-05-16       Impact factor: 3.576

3.  A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment.

Authors:  A Karimi Rahmati; S K Setarehdan; B N Araabi
Journal:  J Biomed Phys Eng       Date:  2017-03-01

4.  A Novel Technique for Fetal ECG Extraction Using Single-Channel Abdominal Recording.

Authors:  Nannan Zhang; Jinyong Zhang; Hui Li; Omisore Olatunji Mumini; Oluwarotimi Williams Samuel; Kamen Ivanov; Lei Wang
Journal:  Sensors (Basel)       Date:  2017-02-24       Impact factor: 3.576

5.  Invariant heart beat span versus variant heart beat intervals and its application to fetal ECG extraction.

Authors:  Huawen Yan; Hongxing Liu; Xiaolin Huang; Ying Zhao; Junfeng Si; Tiebing Liu
Journal:  Biomed Eng Online       Date:  2014-12-12       Impact factor: 2.819

6.  Dedicated Algorithm for Unobtrusive Fetal Heart Rate Monitoring Using Multiple Dry Electrodes.

Authors:  Alessandra Galli; Elisabetta Peri; Yijing Zhang; Rik Vullings; Myrthe van der Ven; Giada Giorgi; Sotir Ouzounov; Pieter J A Harpe; Massimo Mischi
Journal:  Sensors (Basel)       Date:  2021-06-23       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.