Intraneural or extraneural: diagnostic accuracy of ultrasound assessment for localizing low-volume injection.

Annelot C Krediet1, Nizar Moayeri, Ronald L A W Bleys, Gerbrand J Groen.   

Abstract

BACKGROUND AND OBJECTIVES: When one is performing ultrasound-guided peripheral nerve blocks, it is common to inject a small amount of fluid to confirm correct placement of the needle tip. If an intraneural needle tip position is detected, the needle can then be repositioned to prevent injection of a large amount of local anesthetic into the nerve. However, it is unknown if anesthesiologists can accurately discriminate intraneural and extraneural injection of small volumes. Therefore, this study was conducted to determine the diagnostic accuracy of ultrasound assessment using a criterion standard and to compare experts and novices in ultrasound-guided regional anesthesia.
METHODS: A total of 32 ultrasound-guided infragluteal sciatic nerve blocks were performed on 21 cadaver legs. The injections were targeted to be intraneural (n = 18) or extraneural (n = 14), and 0.5 mL of methylene blue 1% was injected. Cryosections of the nerve and surrounding tissue were assessed by a blinded investigator as "extraneural" or "intraneural." Ultrasound video clips of the injections were reviewed by 10 blinded observers (5 experts, 5 novices) independently who scored each injection as either "intraneural," "extraneural," or "undetermined."
RESULTS: The mean sensitivity of experts and novices was measured to be 0.84 (0.80-0.88) and 0.65 (0.60-0.71), respectively (P = 0.006), whereas mean specificity was 0.97 (0.94-0.98) and 0.98 (0.96-0.99) (P = 0.53).
CONCLUSIONS: Discrimination of intraneural or extraneural needle tip position based on an injection of 0.5mL is possible, but even experts missed 1 of 6 intraneural injections. In novices, the sensitivity of assessment was significantly lower, highlighting the need for focused education.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25068413     DOI: 10.1097/AAP.0000000000000124

Source DB:  PubMed          Journal:  Reg Anesth Pain Med        ISSN: 1098-7339            Impact factor:   6.288


  2 in total

Review 1.  An update around the evidence base for the lower extremity ultrasound regional block technique.

Authors:  Andrea Fanelli; Daniela Ghisi; Rita Maria Melotti
Journal:  F1000Res       Date:  2016-01-26

2.  A randomized trial to determine the minimum effective lidocaine volume for median nerve block using hydrodissection.

Authors:  Eric Dufour; Souhail Jaziri; Marie Alice Novillo; Lila Aubert; Anne Chambon; Rainer Kutz; Alexandre Vallée; Marc Fischler
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.