Evaluation of detection sensitivity in comprehensive two-dimensional liquid chromatography separations of an active pharmaceutical ingredient and its degradants.

Dwight R Stoll1, Eric S Talus, David C Harmes, Kelly Zhang.   

Abstract

In this paper, we describe the findings of a study aimed at assessing the detection sensitivity of comprehensive two-dimensional high-performance liquid chromatography (LCxLC) separation of a degraded active pharmaceutical ingredient (API) with UV absorption as the detection technique. Specifically, we have examined the impact of the volume and solvent composition (referred to as "interface conditions") of fractions of first-dimension column effluent transferred to the second dimension for further separation on the ability to resolve and detect low-abundance compounds. Historically, LCxLC has been perceived as being inferior to 1D-LC from the point of view of detection sensitivity. In this work, we demonstrate that LCxLC is sufficiently sensitive to be useful in the pharmaceutical context where in general impurities present at 0.05 % (relative to the API concentration) should be quantified. Moreover, we find that this level of sensitivity is only attained under certain conditions: dilution of the first column effluent with weak solvent (water in this case) prior to injection into the second-dimension column is very beneficial because it promotes focusing of the analyte band in the second column, thereby improving the detection sensitivity of the LCxLC system; and, quantitation limits are also a strong function of peak location in the second-dimension separation window, where baseline disturbances near the dead time of the second column can limit reliable detection of low-abundance compounds.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25064601     DOI: 10.1007/s00216-014-8036-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  A tandem liquid chromatography and tandem mass spectrometry (LC/LC-MS/MS) technique to separate and quantify steroid isomers 11β-methyl-19-nortestosterone and testosterone.

Authors:  Liang Tang; Robert R Swezey; Carol E Green; Min S Lee; Deborah I Bunin; Toufan Parman
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2022-02-09       Impact factor: 3.318

2.  Quantitative evaluation of models for solvent-based, on-column focusing in liquid chromatography.

Authors:  Stephen R Groskreutz; Stephen G Weber
Journal:  J Chromatogr A       Date:  2015-07-14       Impact factor: 4.759

Review 3.  Optimizing separations in online comprehensive two-dimensional liquid chromatography.

Authors:  Bob W J Pirok; Andrea F G Gargano; Peter J Schoenmakers
Journal:  J Sep Sci       Date:  2017-11-23       Impact factor: 3.645