Literature DB >> 25063932

Quantitative comparison of striated toolmarks.

Martin Baiker1, Isaac Keereweer2, René Pieterman3, Erwin Vermeij4, Jaap van der Weerd5, Peter Zoon6.   

Abstract

A comparison of striated toolmarks by human examiners is dependent on the experience of the expert and includes a subjective judgment within the process. In this article an automated method is presented for objective comparison of striated marks of screwdrivers. The combination of multi-scale registration (alignment) of toolmarks, that accounts for shift and scaling, with global cross correlation as objective toolmark similarity metric renders the approach robust with respect to large differences in angle of attack and moderate toolmark compression. In addition, a strategy to distinguish between relevant and non-relevant spatial frequency ranges (geometric details) is presented. The performance of the method is evaluated using 3D topography scans of experimental toolmarks of 50 unused screwdrivers. Known match and known non-match similarity distributions are estimated including a large range of angles of attack (15, 30, 45, 60 and 75°) for the known matches. It is demonstrated that the system has high discriminatory power, even if the toolmarks are made at a difference in angle of attack of larger than 15°. The probability distributions are subsequently employed to determine likelihood ratios. A comparison of the results of the automated method with the outcome of a toolmark comparison experiment involving three experienced toolmark examiners reveals, that the automated system is more powerful in correctly supporting the hypothesis of common origin for toolmarks with a large difference in angle of attack (30°). In return, the rate of toolmark comparisons that yield incorrect support for the hypothesis of common origin is higher for the automated system. In addition, a comparison between estimating known match and known non-match distributions using 2D and 3D data is presented and it is shown that for toolmarks of unused screwdrivers, relying on 3D is slightly better than relying on 2D data. Finally, a comparison between estimating known match and known non-match distributions for two different types of screwdrivers suggests, that the method may be used for comparing marks of other tools as well.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  2D/3D data; Likelihood ratio; Objective screwdriver toolmark comparison; Sub-class identification; Toolmark registration/alignment; Toolmark variability and repeatability

Mesh:

Year:  2014        PMID: 25063932     DOI: 10.1016/j.forsciint.2014.06.038

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  5 in total

1.  Sharp force trauma with two katana swords: identifying the murder weapon by comparing tool marks on the skull bone.

Authors:  Matthias Weber; Sibylle Banaschak; Markus Alexander Rothschild
Journal:  Int J Legal Med       Date:  2020-07-13       Impact factor: 2.686

Review 2.  Interpol review of shoe and tool marks 2016-2019.

Authors:  Martin Baiker-Sørensen; Koen Herlaar; Isaac Keereweer; Petra Pauw-Vugts; Richard Visser
Journal:  Forensic Sci Int       Date:  2020-04-02       Impact factor: 2.395

3.  Insights to enhance the examination of tool marks in human cartilage.

Authors:  Matthias Weber; Anja Niehoff; Markus A Rothschild
Journal:  Int J Legal Med       Date:  2021-05-13       Impact factor: 2.686

4.  Quantitative matching of forensic evidence fragments utilizing 3D microscopy analysis of fracture surface replicas.

Authors:  Bishoy Dawood; Carlos Llosa-Vite; Geoffrey Z Thompson; Barbara K Lograsso; Lauren K Claytor; John Vanderkolk; William Meeker; Ranjan Maitra; Ashraf Bastawros
Journal:  J Forensic Sci       Date:  2022-03-07       Impact factor: 1.717

5.  Topography measurements and applications in ballistics and tool mark identifications.

Authors:  T V Vorburger; J Song; N Petraco
Journal:  Surf Topogr       Date:  2015-12-17       Impact factor: 2.038

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.