Literature DB >> 25063466

Diagnostic value of three-dimensional contrast-enhanced echocardiography for left ventricular volume and ejection fraction measurement in patients with poor acoustic windows: a comparison of echocardiography and magnetic resonance imaging.

Eric Saloux1, Fabien Labombarda2, Arnaud Pellissier2, Bruno Anthune2, Audrey Emmanuelle Dugué3, Nicole Provost4, Pascal Allain5, Mathieu De Craene5, Paul Milliez6, Alain Manrique7.   

Abstract

BACKGROUND: Three-dimensional echocardiography (3DE) is a reliable and reproducible tool for assessing left ventricular (LV) function but remains sensitive to patient echogenicity. Contrast-enhanced 3DE (C3DE) has the potential to improve quantification in challenging patients. The aim of this study was to evaluate the impact of temporal resolution, spatial resolution, and image dynamic range on LV function assessed using C3DE compared with cardiac magnetic resonance imaging (MRI) in patients with poor echogenicity.
METHODS: Forty-one patients with poor echogenicity who underwent two-dimensional echocardiography (2DE), 3DE, C3DE, and MRI were retrospectively investigated.
RESULTS: Before contrast injection, 24 patients had three or more nonvisible segments. Three cases of 2DE and 12 cases of 3DE were not suitable for quantification. LV end-diastolic volumes were systematically underestimated by 2DE (142 ± 58 mL), 3DE (146 ± 69 mL), and C3DE (172 ± 61 mL) compared with MRI (216 ± 85 mL) (P < .001). Similar results were found for LV end-systolic volumes (81 ± 65 mL for 2DE, 82 ± 69 mL for 3DE, and 102 ± 80 mL for C3DE vs 129 ± 94 mL for MRI; P < .001). C3DE provided the best agreement with MRI (Lin concordance correlation coefficients of 0.67, 0.93, and 0.99, respectively, for end-diastolic volume, end-systolic volume, and ejection fraction) as well as the best measurement reproducibility. Finally, ultrasound settings had no significant effect on LV volumes and ejection fraction measurements.
CONCLUSIONS: In these patients with poor ultrasound image quality, C3DE, regardless of instrument settings, outperformed 2DE and 3DE to assess LV volumes and ejection fraction and can thus be proposed as an acceptable alternative when MRI cannot be performed in this subgroup.
Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cardiac magnetic resonance; Three-dimensional contrast-enhanced echocardiography; Three-dimensional echocardiography

Mesh:

Substances:

Year:  2014        PMID: 25063466     DOI: 10.1016/j.echo.2014.06.006

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  10 in total

1.  Left and Right Ventricular Functional Dynamics Determined by Echocardiograms Before and After Lung Transplantation.

Authors:  Tomoko S Kato; Hilary F Armstrong; P Christian Schulze; Matthew Lippel; Atsushi Amano; Maryjane Farr; Matthew Bacchetta; Matthew N Bartels; Marco R Di Tullio; Shunichi Homma; Donna Mancini
Journal:  Am J Cardiol       Date:  2015-05-21       Impact factor: 2.778

Review 2.  Echocardiographic assessment of myocardial ischemia.

Authors:  Roman Leischik; Birgit Dworrak; Fabian Sanchis-Gomar; Alejandro Lucia; Thomas Buck; Raimund Erbel
Journal:  Ann Transl Med       Date:  2016-07

3.  Protective effects of Phyllanthus emblica against myocardial ischemia-reperfusion injury: the role of PI3-kinase/glycogen synthase kinase 3β/β-catenin pathway.

Authors:  Mahesh Thirunavukkarasu; Vaithinathan Selvaraju; Leonidas Tapias; Juan A Sanchez; J Alexander Palesty; Nilanjana Maulik
Journal:  J Physiol Biochem       Date:  2015-09-05       Impact factor: 4.158

Review 4.  Status and potential clinical value of a transthoracic evaluation of the coronary arteries.

Authors:  Fabien Labombarda; Samuela Castelnuovo; Dionysis Goularas; Cesare R Sirtori
Journal:  Cardiovasc Ultrasound       Date:  2016-01-19       Impact factor: 2.062

5.  Assessment of left ventricular function in chronic alcoholics by real-time three-dimensional echocardiography.

Authors:  Yuanzheng Wang; Guoxin Shan; Jiaqi Shen; Qiao Zhou; Bijun Tan; Yue Liu; Runlan Luo; Shifen Zhao; Wenjun Bi; Fangyi Yao; Guangsen Li
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

6.  Evaluation of changes in left ventricular structure and function in hypertensive patients with coronary artery disease after PCI using real-time three-dimensional echocardiography.

Authors:  Yanhong Meng; Ling Zong; Ziteng Zhang; Youdong Han; Yanhui Wang
Journal:  Exp Ther Med       Date:  2017-11-22       Impact factor: 2.447

Review 7.  Contrast echocardiography in daily clinical practice.

Authors:  M Eskandari; M Monaghan
Journal:  Herz       Date:  2017-05       Impact factor: 1.443

8.  Coronary slow flow: Benign or ominous?

Authors:  Mohammed Omer Anwar; Yasser Al Omran
Journal:  Anatol J Cardiol       Date:  2016-01       Impact factor: 1.596

9.  Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Authors:  Jonas Jenner; Peder Sörensson; John Pernow; Kenneth Caidahl; Maria J Eriksson
Journal:  Clin Med Insights Cardiol       Date:  2019-03-05

10.  Echocardiography and cardiac resynchronisation therapy, friends or foes?

Authors:  W M van Everdingen; J C Schipper; J van 't Sant; K Ramdat Misier; M Meine; M J Cramer
Journal:  Neth Heart J       Date:  2016-01       Impact factor: 2.380

  10 in total