Literature DB >> 25062807

Trends in total hip arthroplasty implant utilization in the United States.

Mandeep S Lehil1, Kevin J Bozic2.   

Abstract

Total hip arthroplasty (THA) implant usage has evolved as experience has been gained with newer implant designs. The purpose of this study was to characterize trends in THA implant usage between 2001 and 2012. The Orthopedic Research Network, which includes 174 hospitals and ~105,000 THA, was used to evaluate trends in fixation, bearings, acetabular cup and liner, and femoral head usage. In 2012, 93% of THAs were cementless; 56% of THA bearings were metal-HXLPE; and 35% were ceramic-HXLPE. 99% of acetabular cups were modular. 61% of femoral heads were metal, 39% were ceramic, 51% were 36mm, and 28% were 32mm. THA implant usage trends favor cementless fixation, metal-on-polyethylene or ceramic-on-polyethylene bearings, modular acetabular cups, and large diameter femoral heads.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  THA; implant; total hip arthroplasty; trend; utilization

Mesh:

Year:  2014        PMID: 25062807     DOI: 10.1016/j.arth.2014.05.017

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  36 in total

Review 1.  [Periprosthetic infections of the hip joint : Clinical approach].

Authors:  H M L Mühlhofer; H Gollwitzer; F Lenze; S Feihl; F Pohlig; R von Eisenhart-Rothe; J Schauwecker
Journal:  Orthopade       Date:  2015-05       Impact factor: 1.087

2.  Femoral revision for periprosthetic fracture in total hip arthroplasty.

Authors:  Luke G Menken; Jose A Rodriguez
Journal:  J Clin Orthop Trauma       Date:  2019-12-14

3.  Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.

Authors:  Seung-Jae Lim; Seung-Pil Jang; Dong-Wook Kim; Young-Wan Moon; Youn-Soo Park
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

4.  The Impact of Femoral Component Cementation on Fracture and Mortality Risk in Elective Total Hip Arthroplasty: Analysis from a National Medicare Sample.

Authors:  Adam I Edelstein; Eric L Hume; Liliana E Pezzin; Emily L McGinley; Timothy R Dillingham
Journal:  J Bone Joint Surg Am       Date:  2022-03-16       Impact factor: 5.284

5.  Osteogenic potential of human adipose-tissue-derived mesenchymal stromal cells cultured on 3D-printed porous structured titanium.

Authors:  Eric A Lewallen; Dakota L Jones; Amel Dudakovic; Roman Thaler; Christopher R Paradise; Hilal M Kremers; Matthew P Abdel; Sanjeev Kakar; Allan B Dietz; Robert C Cohen; David G Lewallen; Andre J van Wijnen
Journal:  Gene       Date:  2016-01-13       Impact factor: 3.688

6.  Metal-on-metal total hip arthroplasty: is there still a role in 2016?

Authors:  Edward J Silverman; Blair Ashley; Neil P Sheth
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

7.  Gender Differences in Wear Rates for 28- vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty.

Authors:  Jeffrey B Stambough; Gail Pashos; Ningying Wu; Jacob A Haynes; John M Martell; John C Clohisy
Journal:  J Arthroplasty       Date:  2015-10-28       Impact factor: 4.757

8.  The Ganz acetabular reinforcement ring shows excellent long-term results when used as a primary implant: a retrospective analysis of two hundred and forty primary total hip arthroplasties with a minimum follow-up of twenty years.

Authors:  Marc C Attinger; Pascal C Haefeli; Henrik C Bäcker; Remy Flueckiger; Peter M Ballmer; Klaus A Siebenrock; Frank M Klenke
Journal:  Int Orthop       Date:  2019-01-20       Impact factor: 3.075

9.  Perioperative factors associated with increased length of stay after revision of metal-on-metal total hip arthroplasty.

Authors:  Jonathan H Garfinkel; Brian P Gladnick; Cole S Pachter; Niall H Cochrane; David W Romness
Journal:  J Orthop       Date:  2019-01-17

10.  Clinical and radiographic outcomes with the Nanos™ short-stem hip implant at 24 months: A prospective, single-center study.

Authors:  Stefan Budde; Michael Schwarze; Thilo Floerkemeier; Jochen Plagge; Nils Wirries; Henning Windhagen; Fritz Thorey; Alexander Derksen
Journal:  J Orthop       Date:  2020-06-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.