Literature DB >> 25061830

Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

Patrik Zamecnik1, Martijn G Schouten, Axel J Krafft, Florian Maier, Heinz-Peter Schlemmer, Jelle O Barentsz, Michael Bock, Jurgen J Fütterer.   

Abstract

PURPOSE: To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies.
MATERIALS AND METHODS: This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed.
RESULTS: Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer.
CONCLUSION: This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25061830     DOI: 10.1148/radiol.14132067

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

Review 1.  Techniques and Outcomes of MRI-TRUS Fusion Prostate Biopsy.

Authors:  Masatomo Kaneko; Dordaneh Sugano; Amir H Lebastchi; Vinay Duddalwar; Jamal Nabhani; Christopher Haiman; Inderbir S Gill; Giovanni E Cacciamani; Andre Luis Abreu
Journal:  Curr Urol Rep       Date:  2021-03-22       Impact factor: 3.092

2.  Simultaneous slice excitation for accelerated passive marker tracking via phase-only cross correlation (POCC) in MR-guided needle interventions.

Authors:  Andreas Reichert; Michael Bock; Simon Reiss; Christiaan G Overduin; Jurgen J Fütterer; Axel Joachim Krafft
Journal:  MAGMA       Date:  2018-09-06       Impact factor: 2.310

Review 3.  The Current State of MR Imaging-targeted Biopsy Techniques for Detection of Prostate Cancer.

Authors:  Sadhna Verma; Peter L Choyke; Steven C Eberhardt; Aytekin Oto; Clare M Tempany; Baris Turkbey; Andrew B Rosenkrantz
Journal:  Radiology       Date:  2017-11       Impact factor: 11.105

Review 4.  Computer-aided Detection of Prostate Cancer with MRI: Technology and Applications.

Authors:  Lizhi Liu; Zhiqiang Tian; Zhenfeng Zhang; Baowei Fei
Journal:  Acad Radiol       Date:  2016-04-25       Impact factor: 3.173

5.  Real-time probe tracking using EM-optical sensor for MRI-guided cryoablation.

Authors:  Wenpeng Gao; Baichuan Jiang; Daniel F Kacher; Barry Fetics; Erez Nevo; Thomas C Lee; Jagadeesan Jayender
Journal:  Int J Med Robot       Date:  2017-11-28       Impact factor: 2.547

6.  Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

Authors:  Christiaan G Overduin; Jan Heidkamp; Eva Rothgang; Jelle O Barentsz; Frank de Lange; Jurgen J Fütterer
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

7.  GantryMate: A Modular MR-Compatible Assistance System for MR-Guided Needle Interventions.

Authors:  Andreas Reichert; Michael Bock; Michael Vogele; Axel Joachim Krafft
Journal:  Tomography       Date:  2019-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.