Literature DB >> 25060820

Cardiac implanted electronic device-related infective endocarditis: clinical features, management, and outcomes of 80 consecutive patients.

David H Kim1, Jesalyn Tate, William F Dresen, Frank C Papa, Karen C Bloch, Spyros A Kalams, Christopher R Ellis, Michael T Baker, Daniel J Lenihan, Lisa A Mendes.   

Abstract

BACKGROUND: The use of cardiac implantable electronic devices (CIEDs) has expanded dramatically over the past decade, but net clinical benefit has been curtailed by increasing infectious complications. In particular, CIED-related infectious endocarditis (IE) is a serious condition with significant morbidity and mortality.
METHODS: We performed a single-center, retrospective study between July 2006 and February 2011 with CIED-related IE, defined by either lead vegetations detected on echocardiography or by fulfilling Duke criteria for definite endocarditis. Clinical parameters and outcomes were detailed by electronic medical record review and vital status was confirmed by the Social Security Death Index.
RESULTS: Eighty patients (median age 67, interquartile range 56-75, 58 M/22 F) were diagnosed with CIED-related IE. Overall mortality was 36% with a median time to death of 95 days from presentation. Over half (52%) of the deaths were infection related with a median time to death of 29 days. Multivariate analysis showed methicillin-resistant Staphylococcus aureus (MRSA) infection (odds ratio [OR] 0.158; 95% confidence interval [CI], 0.047-0.534; P = .003) and concomitant valve endocarditis (OR 0.141, CI 0.041-0.491, P = .002) independently predicted mortality.
CONCLUSION: In this contemporary series, all-cause mortality in patients with CIED-related IE was high with a short time to death from onset of infection. MRSA and concomitant valve infection were the most powerful independent predictors of mortality. ©2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  ICD; echocardiography; endocarditis; pacemaker

Mesh:

Year:  2014        PMID: 25060820     DOI: 10.1111/pace.12452

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

2.  Clinical Profile and Outcome of Patients with Cardiac Implantable Electronic Device-Related Infection.

Authors:  Alessandra de Souza Maciel; Rose Mary Ferreira Lisboa da Silva
Journal:  Arq Bras Cardiol       Date:  2021-06       Impact factor: 2.000

3.  Prognostic Value of Preoperative Echocardiographic Findings in Patients Undergoing Transvenous Lead Extraction.

Authors:  Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Łukasz Tułecki; Andrzej Kleinrok; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2021-02-14       Impact factor: 3.390

Review 4.  Multimodality Imaging in the Diagnosis of Prosthetic Valve Endocarditis: A Brief Review.

Authors:  Maxwell D Eder; Krishna Upadhyaya; Jakob Park; Matthew Ringer; Maricar Malinis; Bryan D Young; Lissa Sugeng; David J Hur
Journal:  Front Cardiovasc Med       Date:  2021-12-20

Review 5.  Native valve, prosthetic valve, and cardiac device-related infective endocarditis: A review and update on current innovative diagnostic and therapeutic strategies.

Authors:  Joop J P Kouijzer; Daniëlle J Noordermeer; Wouter J van Leeuwen; Nelianne J Verkaik; Kirby R Lattwein
Journal:  Front Cell Dev Biol       Date:  2022-10-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.