Literature DB >> 25059625

Assessment of image quality in real time three-dimensional dobutamine stress echocardiography: an integrated 2D/3D approach.

Amer M Johri1, David W Chitty, Lanqi Hua, Gergana Marincheva, Michael H Picard.   

Abstract

BACKGROUND: Three-dimensional (3D) stress echocardiography is a relatively new technique offering the potential to acquire images of the entire left ventricle from 1 or 2 transducer positions in a time-efficient manner. Relative to two-dimensional (2D) imaging, the ability to quickly acquire full volume images during peak stress with 3D echocardiography can eliminate left ventricular (LV) foreshortening while reducing inter-operator variability. Our objectives were to (1) determine the practicality of a novel integrated 2D/3D stress protocol in incorporating 3D imaging into a standard 2D stress echocardiogram and (2) to determine whether the quality of imaging using the novel 2D/3D protocol was sufficient for interpretation.
METHODS: Twenty-five patients referred for stress echocardiography underwent an integrated 2D/3D image acquisition protocol. LV segments were scored from 0 (absent or no clear endocardial visualization) to 3 (excellent/full visualization of endocardial border) with each modality. 2D segment quality scoring was compared with 3D. An integrated score was compared with either 2D or 3D imaging alone.
RESULTS: Two-dimensional and 3D imaging were optimal for differing segments and the integrated protocol was superior to either modality alone. 3D imaging was superior in visualizing the anterior and anterolateral region of the base segments, compared to 2D imaging. 3D imaging was less useful for the base, the mid-inferior, and the inferoseptal segments, thus emphasizing the need to retain 2D imaging in stress echocardiography at this time.
CONCLUSION: The integrated 2D/3D protocol approach to stress echocardiography is technically feasible and maximizes image quality of dobutamine stress echocardiography, improving patient assessment.
© 2014, Wiley Periodicals, Inc.

Entities:  

Keywords:  dobutamine; echocardiography; integrated protocol; quality; stress test; three-dimensional

Mesh:

Substances:

Year:  2014        PMID: 25059625     DOI: 10.1111/echo.12692

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

Review 1.  Stress echocardiography: what is new and how does it compare with myocardial perfusion imaging and other modalities?

Authors:  Marysia S Tweet; Adelaide M Arruda-Olson; Nandan S Anavekar; Patricia A Pellikka
Journal:  Curr Cardiol Rep       Date:  2015-06       Impact factor: 2.931

2.  Intraobserver and interobserver reproducibility of M-mode and B-mode acquired mitral annular plane systolic excursion (MAPSE) and its dependency on echocardiographic image quality in children.

Authors:  Kai O Hensel; Markus Roskopf; Lucia Wilke; Andreas Heusch
Journal:  PLoS One       Date:  2018-05-10       Impact factor: 3.240

3.  Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality.

Authors:  Lucia Wilke; Francisca E Abellan Schneyder; Markus Roskopf; Andreas C Jenke; Andreas Heusch; Kai O Hensel
Journal:  Sci Rep       Date:  2018-06-15       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.