Literature DB >> 25059598

Evaluation of a 32-channel versus a 12-channel head coil for high-resolution post-contrast MRI in giant cell arteritis (GCA) at 3T.

Philipp Franke1, Michael Markl2, Sonja Heinzelmann3, Peter Vaith4, Jonas Bürk5, Mathias Langer6, J Geiger7.   

Abstract

The aim of this study was to evaluate the diagnostic value of a 32-channel head coil for the characterization of mural inflammation patterns in the superficial cranial arteries in patients with giant cell arteritis (GCA) compared to a standard 12-channel coil at 3T MRI. 55 patients with suspected GCA underwent high resolution T1-weighted post-contrast MRI at 3T to detect inflammation related vessel wall enhancement using both coils. To account for different time delays between contrast agent injection and sequence acquisition, the patients were divided into two cohorts: 27 patients were examined with the 32-channel coil first and 28 patients with the 12-channel coil first. Images were evaluated by two blinded readers with regard to image quality, artifact level and arteries' inflammation according to a standardized ranking scale; furthermore signal-to-noise ratio (SNR) measurements were performed at three locations. Identification of arteries' inflammation was achieved with both coils with excellent inter-observer agreement (κ=0.89 for 12-channel and κ=0.96 for 32-channel coil). Regarding image grading, the inter-observer variability was moderate for the 12-channel (κ=0.5) and substantial for the 32-channel coil (κ=0.63). Significantly higher SNR and improved image quality (p<0.01) were obtained with the 32-channel coil in either coil order. Image quality for depiction of the superficial cranial arteries was superior for the 32-channel coil. For standardized GCA diagnosis, the 12-channel coil was sufficient.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  12-Channel coil; 32-Channel coil; Giant cell arteritis; Image quality; Inflammation; SNR

Mesh:

Substances:

Year:  2014        PMID: 25059598     DOI: 10.1016/j.ejrad.2014.06.022

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

Review 1.  High-resolution vessel wall MRI for the evaluation of intracranial atherosclerotic disease.

Authors:  Adam de Havenon; Mahmud Mossa-Basha; Lubdha Shah; Seong-Eun Kim; Min Park; Dennis Parker; J Scott McNally
Journal:  Neuroradiology       Date:  2017-09-23       Impact factor: 2.804

Review 2.  Imaging in Giant Cell Arteritis.

Authors:  Asad Khan; Bhaskar Dasgupta
Journal:  Curr Rheumatol Rep       Date:  2015-08       Impact factor: 4.592

3.  A semiflexible 64-channel receive-only phased array for pediatric body MRI at 3T.

Authors:  Tao Zhang; Thomas Grafendorfer; Joseph Y Cheng; Peigang Ning; Bob Rainey; Mark Giancola; Sarah Ortman; Fraser J Robb; Paul D Calderon; Brian A Hargreaves; Michael Lustig; Greig C Scott; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2015-09-29       Impact factor: 4.668

4.  Test-retest variability of brain morphometry analysis: an investigation of sequence and coil effects.

Authors:  Shuang Yan; Tianyi Qian; Bénédicte Maréchal; Tobias Kober; Xianchang Zhang; Jinxia Zhu; Jing Lei; Mingli Li; Zhengyu Jin
Journal:  Ann Transl Med       Date:  2020-01

5.  Imaging in diagnosis, outcome prediction and monitoring of large vessel vasculitis: a systematic literature review and meta-analysis informing the EULAR recommendations.

Authors:  Christina Duftner; Christian Dejaco; Alexandre Sepriano; Louise Falzon; Wolfgang Andreas Schmidt; Sofia Ramiro
Journal:  RMD Open       Date:  2018-02-02
  5 in total