Literature DB >> 25059190

Microextraction of non-steroidal anti-inflammatory drugs from waste water samples by rotating-disk sorptive extraction.

Valentina Manzo1, Luis Honda1, Orielle Navarro1, Loreto Ascar1, Pablo Richter2.   

Abstract

In this study, six non-steroidal anti-inflammatory drugs (NSAIDs) were extracted from water samples using the rotating-disk sorptive extraction (RDSE) technique. The extraction disk device contains a central cavity that allows for the incorporation of a powdered sorbent phase (Oasis™ HLB). The analytes were extracted from water and pre-concentrated on the sorbent to reach the extraction equilibrium, and then they were desorbed with solvent, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). The variables for the extraction were studied using high performance liquid chromatography with a diode array detector (HPLC-DAD) to avoid the derivatization step, and the optimum values were as follows: 60 mg of Oasis™ HLB, a rotation velocity of 3,000 rpm, a pH of 2, a sample volume of 50 mL, and an extraction time of approximately 90-100 min. The recoveries ranged from 71 to 104%, with relative standard deviations (RSD) between 2 and 8%. The detection limits ranged from 0.001 to 0.033 µg L(-1). The described method was applied to the analysis of influents and effluents from wastewater treatment plants (WWTP) in Santiago, Chile. The concentrations of the detected drugs ranged from 1.5 to 13.4 µg L(-1) and from 1.0 to 3.2 µg L(-1) in the influents and effluents, respectively. The samples were extracted by solid phase extraction (SPE). No significant differences were observed in the determined concentrations for most of the NSAIDs, indicating that RDSE is an alternative method for the preparation of water samples.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  GC–MS.; NSAIDs; Oasis™ HLB; Rotating-disk sorptive extraction; Water samples

Mesh:

Substances:

Year:  2014        PMID: 25059190     DOI: 10.1016/j.talanta.2014.06.003

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  A magnetic adsorbent grafted with pendant naphthyl polymer brush for enrichment of the nonsteroidal anti-inflammatory drugs indomethacin and diclofenac.

Authors:  Ya'nan Deng; Jiwei Shen; Jiawei Liu; Yinmao Wei; Chaozhan Wang
Journal:  Mikrochim Acta       Date:  2018-07-09       Impact factor: 5.833

2.  A molecularly imprinted electrochemical aptasensor based on zinc oxide and co-deposited gold nanoparticles/reduced graphene oxide composite for detection of amoxicillin.

Authors:  Huan Lu; Yan Huang; Hanyue Cui; Li Li; Yaping Ding
Journal:  Mikrochim Acta       Date:  2022-10-17       Impact factor: 6.408

3.  Green-synthesized copper nano-adsorbent for the removal of pharmaceutical pollutants from real wastewater samples.

Authors:  Dalal Z Husein; Reda Hassanien; Mostafa F Al-Hakkani
Journal:  Heliyon       Date:  2019-08-21

4.  Preparation of Methacrylate-based Polymers Modified with Chiral Resorcinarenes and Their Evaluation as Sorbents in Norepinephrine Microextraction.

Authors:  Alver Castillo-Aguirre; Mauricio Maldonado
Journal:  Polymers (Basel)       Date:  2019-08-30       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.