Literature DB >> 25059173

Real-time analysis of self-assembled nucleobases by Venturi easy ambient sonic-spray ionization mass spectrometry.

Na Na1, Ruixia Shi2, Zi Long1, Xin Lu3, Fubin Jiang4, Jin Ouyang5.   

Abstract

In this study, the real-time analysis of self-assembled nucleobases was employed by Venturi easy ambient sonic-spray ionization mass spectrometry (V-EASI-MS). With the analysis of three nucleobases including 6-methyluracil (6MU), uracil (U) and thymine (T) as examples, different orders of clusters centered with different metal ions were recorded in both positive and negative modes. Compared with the results obtained by traditional electrospray ionization mass spectrometry (ESI-MS) under the same condition, more clusters with high orders, such as [6MU7+Na](+), [6MU15+2NH4](2+), [6MU10+Na](+), [T7+Na](+), and [T15+2NH4](2+) were detected by V-EASI-MS, which demonstrated the soft ionization ability of V-EASI for studying the non-covalent interaction in a self-assembly process. Furthermore, with the injection of K(+) to the system by a syringe pumping, the real-time monitoring of the formation of nucleobases clusters was achieved by the direct extraction of samples from the system under the Venturi effect. Therefore, the effect of cations on the formation of clusters during self-assembly of nucleobases was demonstrated, which was in accordance with the reports. Free of high voltage, heating or radiation during the ionization, this technique is much soft and suitable for obtaining the real-time information of the self-assembly system, which also makes it quite convenient for extraction samples from the reaction system. This "easy and soft" ionization technique has provided a potential pathway for monitoring and controlling the self-assembly processes.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cations; On-line analysis; Real-time monitoring; Self-assembled nucleobases; Venturi easy ambient sonic-spray ionization mass spectrometry

Mesh:

Substances:

Year:  2014        PMID: 25059173     DOI: 10.1016/j.talanta.2014.04.080

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Monitoring Enzymatic Reactions in Real Time Using Venturi Easy Ambient Sonic-Spray Ionization Mass Spectrometry.

Authors:  Erik T Jansson; Maria T Dulay; Richard N Zare
Journal:  Anal Chem       Date:  2016-06-08       Impact factor: 6.986

2.  FAD roles in glucose catalytic oxidation studied by multiphase flow of extractive electrospray ionization (MF-EESI) mass spectrometry.

Authors:  Yan Wang; Min Sun; Jinping Qiao; Jin Ouyang; Na Na
Journal:  Chem Sci       Date:  2017-10-27       Impact factor: 9.825