Breast cancer screening using tomosynthesis in combination with digital mammography.

Sarah M Friedewald1, Elizabeth A Rafferty2, Stephen L Rose3, Melissa A Durand4, Donna M Plecha5, Julianne S Greenberg6, Mary K Hayes7, Debra S Copit8, Kara L Carlson9, Thomas M Cink10, Lora D Barke11, Linda N Greer12, Dave P Miller13, Emily F Conant14.   

Abstract

IMPORTANCE: Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results.
OBJECTIVE: To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. DESIGN, SETTING, AND PARTICIPANTS: Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. EXPOSURES: Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. MAIN OUTCOMES AND MEASURES: Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy.
RESULTS: A total of 454,850 examinations (n=281,187 digital mammography; n=173,663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29,726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15,541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001); and for invasive cancer detection, 2.9 (95% CI, 2.5-3.2) with digital mammography vs 4.1 (95% CI, 3.7-4.5) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001). The in situ cancer detection rate was 1.4 (95% CI, 1.2-1.6) per 1000 screens with both methods. Adding tomosynthesis was associated with an increase in the positive predictive value for recall from 4.3% to 6.4% (difference, 2.1%; 95% CI, 1.7%-2.5%; P < .001) and for biopsy from 24.2% to 29.2% (difference, 5.0%; 95% CI, 3.0%-7.0%; P < .001). CONCLUSIONS AND RELEVANCE: Addition of tomosynthesis to digital mammography was associated with a decrease in recall rate and an increase in cancer detection rate. Further studies are needed to assess the relationship to clinical outcomes.

Entities:  

Mesh:

Year:  2014        PMID: 25058084     DOI: 10.1001/jama.2014.6095

Source DB:  PubMed          Journal:  JAMA        ISSN: 0098-7484            Impact factor:   56.272


  180 in total

1.  Ductal carcinoma in situ on digital mammography versus digital breast tomosynthesis: rates and predictors of pathologic upgrade.

Authors:  Geunwon Kim; Peter G Mikhael; Tawakalitu O Oseni; Manisha Bahl
Journal:  Eur Radiol       Date:  2020-06-26       Impact factor: 5.315

2.  Listening to Women: Expectations and Experiences in Breast Imaging.

Authors:  Susan Harvey; Aimee M Gallagher; Martha Nolan; Christine M Hughes
Journal:  J Womens Health (Larchmt)       Date:  2015-09       Impact factor: 2.681

3.  Screening: Don't look now.

Authors:  Emily Sohn
Journal:  Nature       Date:  2015-11-19       Impact factor: 49.962

4.  Fully Automated Quantitative Estimation of Volumetric Breast Density from Digital Breast Tomosynthesis Images: Preliminary Results and Comparison with Digital Mammography and MR Imaging.

Authors:  Said Pertuz; Elizabeth S McDonald; Susan P Weinstein; Emily F Conant; Despina Kontos
Journal:  Radiology       Date:  2015-10-21       Impact factor: 11.105

5.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

6.  Collaborative Modeling of the Benefits and Harms Associated With Different U.S. Breast Cancer Screening Strategies.

Authors:  Jeanne S Mandelblatt; Natasha K Stout; Clyde B Schechter; Jeroen J van den Broek; Diana L Miglioretti; Martin Krapcho; Amy Trentham-Dietz; Diego Munoz; Sandra J Lee; Donald A Berry; Nicolien T van Ravesteyn; Oguzhan Alagoz; Karla Kerlikowske; Anna N A Tosteson; Aimee M Near; Amanda Hoeffken; Yaojen Chang; Eveline A Heijnsdijk; Gary Chisholm; Xuelin Huang; Hui Huang; Mehmet Ali Ergun; Ronald Gangnon; Brian L Sprague; Sylvia Plevritis; Eric Feuer; Harry J de Koning; Kathleen A Cronin
Journal:  Ann Intern Med       Date:  2016-01-12       Impact factor: 25.391

7.  Association of Screening and Treatment With Breast Cancer Mortality by Molecular Subtype in US Women, 2000-2012.

Authors:  Sylvia K Plevritis; Diego Munoz; Allison W Kurian; Natasha K Stout; Oguzhan Alagoz; Aimee M Near; Sandra J Lee; Jeroen J van den Broek; Xuelin Huang; Clyde B Schechter; Brian L Sprague; Juhee Song; Harry J de Koning; Amy Trentham-Dietz; Nicolien T van Ravesteyn; Ronald Gangnon; Young Chandler; Yisheng Li; Cong Xu; Mehmet Ali Ergun; Hui Huang; Donald A Berry; Jeanne S Mandelblatt
Journal:  JAMA       Date:  2018-01-09       Impact factor: 56.272

8.  BI-RADS Category 3 Comparison: Probably Benign Category after Recall from Screening before and after Implementation of Digital Breast Tomosynthesis.

Authors:  Elizabeth S McDonald; Anne Marie McCarthy; Susan P Weinstein; Mitchell D Schnall; Emily F Conant
Journal:  Radiology       Date:  2017-07-17       Impact factor: 11.105

9.  Digital Breast Tomosynthesis: Radiologist Learning Curve.

Authors:  Diana L Miglioretti; Linn Abraham; Christoph I Lee; Diana S M Buist; Sally D Herschorn; Brian L Sprague; Louise M Henderson; Anna N A Tosteson; Karla Kerlikowske
Journal:  Radiology       Date:  2019-02-26       Impact factor: 11.105

Review 10.  Artificial Intelligence for Mammography and Digital Breast Tomosynthesis: Current Concepts and Future Perspectives.

Authors:  Krzysztof J Geras; Ritse M Mann; Linda Moy
Journal:  Radiology       Date:  2019-09-24       Impact factor: 11.105

View more