Literature DB >> 25056525

Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

Vilhelm F Koefoed1, Valborg Baste, Corinne Roumes, Gunnar Høvding.   

Abstract

PURPOSE: This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.
METHODS: Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods.
RESULTS: A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03).
CONCLUSION: The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.
© 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Keywords:  contrast sensitivity; medical selection; mesopic vision; photopic vision; visual function; visual quality

Mesh:

Year:  2014        PMID: 25056525     DOI: 10.1111/aos.12487

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  7 in total

1.  Effects of upper lid blepharoplasty on visual quality in patients with lash ptosis and dermatochalasis.

Authors:  Seoung Hyun An; Sang Wook Jin; Yoon Hyung Kwon; Won Yeol Ryu; Woo Jin Jeong; Hee Bae Ahn
Journal:  Int J Ophthalmol       Date:  2016-09-18       Impact factor: 1.779

2.  Comparison of Two Different Contrast Sensitivity Testing Methods in Patients with Low Vision.

Authors:  Deniz Altinbay; Esra Sahli; Aysun Idil
Journal:  J Curr Ophthalmol       Date:  2022-04-16

3.  Evaluation of the precision of contrast sensitivity function assessment on a tablet device.

Authors:  Michael Dorr; Luis A Lesmes; Tobias Elze; Hui Wang; Zhong-Lin Lu; Peter J Bex
Journal:  Sci Rep       Date:  2017-04-21       Impact factor: 4.379

4.  Visual outcomes and safety after bilateral implantation of a trifocal presbyopia correcting intraocular lens in a Korean population: a prospective single-arm study.

Authors:  Tae-Im Kim; Tae-Young Chung; Myoung Joon Kim; Kyounghwa Lee; Joon Young Hyon
Journal:  BMC Ophthalmol       Date:  2020-07-15       Impact factor: 2.209

5.  Mesopic conditions optimise the detection of visual function loss in drivers with simulated media opacity.

Authors:  Frederick A Asare; Roger S Anderson; Pádraig J Mulholland; Julie-Anne Little
Journal:  Sci Rep       Date:  2022-08-01       Impact factor: 4.996

6.  A randomized phase 2 clinical trial of phentolamine mesylate eye drops in patients with severe night vision disturbances.

Authors:  Jay Pepose; Mitchell Brigell; Eliot Lazar; Curtis Heisel; Jonah Yousif; Kavon Rahmani; Ajay Kolli; Min Hwang; Cara Mitrano; Audrey Lazar; Konstantinos Charizanis; Mina Sooch; Marguerite McDonald
Journal:  BMC Ophthalmol       Date:  2022-10-08       Impact factor: 2.086

7.  Effect of Varying Levels of Glare on Contrast Sensitivity Measurements of Young Healthy Individuals Under Photopic and Mesopic Vision.

Authors:  Marcello Maniglia; Steven M Thurman; Aaron R Seitz; Pinakin G Davey
Journal:  Front Psychol       Date:  2018-06-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.