Literature DB >> 25055701

[Sampling methods for PM2.5 from stationary sources: a review].

Jing-Kun Jiang, Jian-Guo Deng, Zhen Li, Xing-Hua Li, Lei Duan, Ji-Ming Hao.   

Abstract

The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25055701

Source DB:  PubMed          Journal:  Huan Jing Ke Xue        ISSN: 0250-3301


  1 in total

1.  Spatio-Temporal Variation Characteristics of PM2.5 in the Beijing-Tianjin-Hebei Region, China, from 2013 to 2018.

Authors:  Lili Wang; Qiulin Xiong; Gaofeng Wu; Atul Gautam; Jianfang Jiang; Shuang Liu; Wenji Zhao; Hongliang Guan
Journal:  Int J Environ Res Public Health       Date:  2019-11-04       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.