Literature DB >> 25053661

Intraaortic balloon pump boon for off-pump coronary artery bypass grafting.

Kamales Kumar Saha1, Ram P Kaushal2, Ajay Kumar3, Mandar Deval4, Kakalee K Saha5, Shibban K Kaul4.   

Abstract

BACKGROUND: Off-pump coronary artery bypass techniques have evolved in the past decade, but there are some concerns about hemodynamic decompensation requiring conversion to cardiopulmonary bypass. These conversions are associated with higher morbidity and mortality. We use an intraaortic balloon pump to treat ischemia-induced hemodynamic instability and arrhythmias during off-pump coronary artery bypass. The objective of this study was to assess the impact of intraaortic balloon pump use in off-pump coronary artery bypass to prevent emergency conversion to cardiopulmonary bypass.
METHODS: Data of 529 consecutive unselected patients who underwent isolated coronary artery bypass were included in this retrospective study of prospectively collected data and operation notes. Complete revascularization was performed using an off-pump technique. All arterial grafts using bilateral internal mammary arteries, and aortic no-touch technique were preferred. If the clinical situation demanded, vein grafts were used. During the procedure, any hemodynamic compromise not responding to conventional inotropic therapy was treated with intraaortic balloon pump insertion.
RESULTS: Complete revascularization was possible in all 529 patients. An intraaortic balloon pump was inserted in 33 (6.2%) patients to treat hemodynamic instability; in all cases, conversion to cardiopulmonary bypass was avoided and complete revascularization was achieved.
CONCLUSION: For treating hemodynamic instability during off-pump coronary artery bypass, we recommend intraaortic balloon pump insertion as the preferred bail-out method rather than conversion to cardiopulmonary bypass.
© The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  CABG; Coronary artery bypass grafting; coronary artery disease; intra-aortic balloon pump; off-pump CABG; off-pump conversion

Mesh:

Year:  2014        PMID: 25053661     DOI: 10.1177/0218492314544158

Source DB:  PubMed          Journal:  Asian Cardiovasc Thorac Ann        ISSN: 0218-4923


  4 in total

1.  Total arterial anaortic off-pump coronary artery bypass grafting for diffuse coronary disease - A case report.

Authors:  Kamales Kumar Saha; Mandar M Deval; Shekhar Ambardekar; Ajay Kumar; Kakalee K Saha
Journal:  Indian Heart J       Date:  2015-05-14

2.  Characteristics, morbidity and mortality factors associated with Intra-Aortic Balloon Pump in Coronary Artery Bypass Graft Surgery patients.

Authors:  Sayed Mumtaz Anwar Shah; Nabil I Awan; Azam Jan; Mujeeb Ur Rehman
Journal:  Pak J Med Sci       Date:  2020 Sep-Oct       Impact factor: 1.088

3.  Total arterial anaortic off-pump coronary artery bypass grafting in a patient with heart failure - Case report.

Authors:  Kamales Kumar Saha; Brian Pinto; Manish Arya; Kakalee K Saha
Journal:  Indian Heart J       Date:  2016-01-12

4.  Anaortic off-pump bilateral internal mammary grafting in severe left ventricular dysfunction - Case report.

Authors:  Kamales Kumar Saha; Saurab Goel; Ajay Kumar; Kakalee K Saha
Journal:  Indian Heart J       Date:  2015-04-27
  4 in total