Energy calibration of the pixels of spectral X-ray detectors.

Raj Kumar Panta, Michael F Walsh, Stephen T Bell, Nigel G Anderson, Anthony P Butler, Philip H Butler.   

Abstract

The energy information acquired using spectral X-ray detectors allows noninvasive identification and characterization of chemical components of a material. To achieve this, it is important that the energy response of the detector is calibrated. The established techniques for energy calibration are not practical for routine use in pre-clinical or clinical research environment. This is due to the requirements of using monochromatic radiation sources such as synchrotron, radio-isotopes, and prohibitively long time needed to set up the equipment and make measurements. To address these limitations, we have developed an automated technique for calibrating the energy response of the pixels in a spectral X-ray detector that runs with minimal user intervention. This technique uses the X-ray tube voltage (kVp) as a reference energy, which is stepped through an energy range of interest. This technique locates the energy threshold where a pixel transitions from not-counting (off) to counting (on). Similarly, we have developed a technique for calibrating the energy response of individual pixels using X-ray fluorescence generated by metallic targets directly irradiated with polychromatic X-rays, and additionally γ-rays from (241)Am. This technique was used to measure the energy response of individual pixels in CdTe-Medipix3RX by characterizing noise performance, threshold dispersion, gain variation and spectral resolution. The comparison of these two techniques shows the energy difference of 1 keV at 59.5 keV which is less than the spectral resolution of the detector (full-width at half-maximum of 8 keV at 59.5 keV). Both techniques can be used as quality control tools in a pre-clinical multi-energy CT scanner using spectral X-ray detectors.

Entities:  

Mesh:

Year:  2014        PMID: 25051546     DOI: 10.1109/TMI.2014.2337881

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Quantitative imaging of excised osteoarthritic cartilage using spectral CT.

Authors:  Kishore Rajendran; Caroline Löbker; Benjamin S Schon; Christopher J Bateman; Raja Aamir Younis; Niels J A de Ruiter; Alex I Chernoglazov; Mohsen Ramyar; Gary J Hooper; Anthony P H Butler; Tim B F Woodfield; Nigel G Anderson
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

2.  Evaluation of a photon counting Medipix3RX cadmium zinc telluride spectral x-ray detector.

Authors:  Jeffrey F Marsh; Steven M Jorgensen; David S Rundle; Andrew J Vercnocke; Shuai Leng; Philip H Butler; Cynthia H McCollough; Erik L Ritman
Journal:  J Med Imaging (Bellingham)       Date:  2018-12-04

3.  Small animal photon counting cone-beam CT on a preclinical radiation research platform to improve radiation dose calculation accuracy.

Authors:  Xiaoyu Hu; Yuncheng Zhong; Youfang Lai; Chenyang Shen; Kai Yang; Xun Jia
Journal:  Phys Med Biol       Date:  2022-09-26       Impact factor: 4.174

4.  Energy Calibration of a CdTe Photon Counting Spectral Detector with Consideration of its Non-Convergent Behavior.

Authors:  Jeong Seok Lee; Dong-Goo Kang; Seung Oh Jin; Insoo Kim; Soo Yeol Lee
Journal:  Sensors (Basel)       Date:  2016-04-11       Impact factor: 3.576

5.  Spectral Photon-Counting Molecular Imaging for Quantification of Monoclonal Antibody-Conjugated Gold Nanoparticles Targeted to Lymphoma and Breast Cancer: An In Vitro Study.

Authors:  Mahdieh Moghiseh; Chiara Lowe; John G Lewis; Dhiraj Kumar; Anthony Butler; Nigel Anderson; Aamir Raja
Journal:  Contrast Media Mol Imaging       Date:  2018-12-18       Impact factor: 3.161

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.