Literature DB >> 25046817

A form-fitted three channel (31) P, two channel (1) H transceiver coil array for calf muscle studies at 7 T.

Sigrun Goluch1,2, Andre Kuehne1,2, Martin Meyerspeer1,2, Roberta Kriegl1,2,3, Albrecht I Schmid1,2, Georg B Fiedler1,2, Tim Herrmann4, Johannes Mallow4, Suk-Min Hong5, Zang-Hee Cho5, Johannes Bernarding4, Ewald Moser1,2, Elmar Laistler1,2.   

Abstract

PURPOSE: To enhance sensitivity and coverage for calf muscle studies, a novel, form-fitted, three-channel phosphorus-31 ((31) P), two-channel proton ((1) H) transceiver coil array for 7 T MR imaging and spectroscopy is presented.
METHODS: Electromagnetic simulations employing individually generated voxel models were performed to design a coil array for studying nonpathological muscle metabolism. Static phase combinations of the coil elements' transmit fields were optimized based on homogeneity and efficiency for several voxel models. The best-performing design was built and tested both on phantoms and in vivo.
RESULTS: Simulations revealed that a shared conductor array for (31) P provides more robust interelement decoupling and better homogeneity than an overlap array in this configuration. A static B1 (+) shim setting that suited various calf anatomies was identified and implemented. Simulations showed that the (31) P array provides signal-to-noise ratio (SNR) benefits over a single loop and a birdcage coil of equal radius by factors of 3.2 and 2.6 in the gastrocnemius and by 2.5 and 2.0 in the soleus muscle.
CONCLUSION: The performance of the coil in terms of B1 (+) and achievable SNR allows for spatially localized dynamic (31) P spectroscopy studies in the human calf. The associated higher specificity with respect to nonlocalized measurements permits distinguishing the functional responses of different muscles.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  31P spectroscopy, EM simulation, coil array, ultra-high field, X-nuclei sensitivity, RF coil design

Mesh:

Substances:

Year:  2014        PMID: 25046817     DOI: 10.1002/mrm.25339

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

Review 1.  MR compatible ergometers for dynamic 31P MRS.

Authors:  Petr Sedivy; Monika Dezortova; Jan Rydlo; Miloslav Drobny; Martin Krssak; Ladislav Valkovic; Milan Hajek
Journal:  J Appl Biomed       Date:  2019-04-15       Impact factor: 1.797

2.  A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy.

Authors:  Matthew Wilcox; Steven M Wright; Mary McDougall
Journal:  IEEE Open J Eng Med Biol       Date:  2020-10-13

3.  Spectral improvement by fourier thresholding of in vivo dynamic spectroscopy data.

Authors:  Benjamin Rowland; Sai K Merugumala; Huijun Liao; Mark A Creager; James Balschi; Alexander P Lin
Journal:  Magn Reson Med       Date:  2015-10-07       Impact factor: 4.668

4.  (31)P CSI of the human brain in healthy subjects and tumor patients at 9.4 T with a three-layered multi-nuclear coil: initial results.

Authors:  Christian Mirkes; Gunamony Shajan; Grzegorz Chadzynski; Kai Buckenmaier; Benjamin Bender; Klaus Scheffler
Journal:  MAGMA       Date:  2016-01-25       Impact factor: 2.310

5.  Localized semi-LASER dynamic (31)P magnetic resonance spectroscopy of the soleus during and following exercise at 7 T.

Authors:  Georg B Fiedler; Martin Meyerspeer; Albrecht I Schmid; Sigrun Goluch; Kiril Schewzow; Elmar Laistler; Arash Mirzahosseini; Fabian Niess; Ewald Unger; Michael Wolzt; Ewald Moser
Journal:  MAGMA       Date:  2015-04-18       Impact factor: 2.310

6.  A radially interleaved sodium and proton coil array for brain MRI at 7 T.

Authors:  Bili Wang; Bei Zhang; Zidan Yu; Carlotta Ianniello; Karthik Lakshmanan; Jan Paska; Guillaume Madelin; Martijn Cloos; Ryan Brown
Journal:  NMR Biomed       Date:  2021-09-03       Impact factor: 4.478

7.  A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T.

Authors:  Matthew Wilcox; Stephen Ogier; Sergey Cheshkov; Ivan Dimitrov; Craig Malloy; Steven Wright; Mary McDougall
Journal:  IEEE Trans Biomed Eng       Date:  2021-05-21       Impact factor: 4.756

8.  Exercising calf muscle T₂∗ changes correlate with pH, PCr recovery and maximum oxidative phosphorylation.

Authors:  Albrecht Ingo Schmid; Kiril Schewzow; Georg Bernd Fiedler; Sigrun Goluch; Elmar Laistler; Michael Wolzt; Ewald Moser; Martin Meyerspeer
Journal:  NMR Biomed       Date:  2014-03-09       Impact factor: 4.044

9.  Feasibility and repeatability of localized (31) P-MRS four-angle saturation transfer (FAST) of the human gastrocnemius muscle using a surface coil at 7 T.

Authors:  Marjeta Tušek Jelenc; Marek Chmelík; Wolfgang Bogner; Martin Krššák; Siegfried Trattnig; Ladislav Valkovič
Journal:  NMR Biomed       Date:  2016-01       Impact factor: 4.044

10.  Skeletal muscle ATP synthesis and cellular H(+) handling measured by localized (31)P-MRS during exercise and recovery.

Authors:  Georg B Fiedler; Albrecht I Schmid; Sigrun Goluch; Kiril Schewzow; Elmar Laistler; Fabian Niess; Ewald Unger; Michael Wolzt; Arash Mirzahosseini; Graham J Kemp; Ewald Moser; Martin Meyerspeer
Journal:  Sci Rep       Date:  2016-08-26       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.