Literature DB >> 25046377

Prediction of micropollutant elimination during ozonation of a hospital wastewater effluent.

Yunho Lee1, Lubomira Kovalova2, Christa S McArdell3, Urs von Gunten4.   

Abstract

Determining optimal ozone doses for organic micropollutant elimination during wastewater ozonation is challenged by the presence of a large number of structurally diverse micropollutants for varying wastewater matrice compositions. A chemical kinetics approach based on ozone and hydroxyl radical (·OH) rate constant and measurements of ozone and ·OH exposures is proposed to predict the micropollutant elimination efficiency. To further test and validate the chemical kinetics approach, the elimination efficiency of 25 micropollutants present in a hospital wastewater effluent from a pilot-scale membrane bioreactor (MBR) were determined at pH 7.0 and 8.5 in bench-scale experiments with ozone alone and ozone combined with H2O2 as a function of DOC-normalized specific ozone doses (gO3/gDOC). Furthermore, ozone and ·OH exposures, ·OH yields, and ·OH consumption rates were determined. Consistent eliminations as a function of gO3/gDOC were observed for micropollutants with similar ozone and ·OH rate constants. They could be classified into five groups having characteristic elimination patterns. By increasing the pH from 7.0 to 8.5, the elimination levels increased for the amine-containing micropollutants due to the increased apparent second-order ozone rate constants while decreased for most micropollutants due to the diminished ozone or ·OH exposures. Increased ·OH quenching by effluent organic matter and carbonate with increasing pH was responsible for the lower ·OH exposures. Upon H2O2 addition, the elimination levels of the micropollutants slightly increased at pH 7 (<8%) while decreased considerably at pH 8.5 (up to 31%). The elimination efficiencies of the selected micropollutants could be predicted based on their ozone and ·OH rate constants (predicted or taken from literature) and the determined ozone and ·OH exposures. Reasonable agreements between the measured and predicted elimination levels were found, demonstrating that the proposed chemical kinetics method can be used for a generalized prediction of micropollutant elimination during wastewater ozonation. Out of 67 analyzed micropollutants, 56 were present in the tested hospital wastewater effluent. Two-thirds of the present micropollutants were found to be ozone-reactive and efficiently eliminated at low ozone doses (e.g., >80% for gO3/gDOC = 0.5).
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Advanced oxidation process; Hospital wastewater; Micropollutant; Ozonation; Pharmaceutical; QSAR

Mesh:

Substances:

Year:  2014        PMID: 25046377     DOI: 10.1016/j.watres.2014.06.027

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  Functional categories of microbial toxicity resulting from three advanced oxidation process treatments during management and disposal of contaminated water.

Authors:  Rebecca B Phillips; Ryan R James; Matthew L Magnuson
Journal:  Chemosphere       Date:  2019-08-09       Impact factor: 7.086

Review 2.  Analytical tools employed to determine pharmaceutical compounds in wastewaters after application of advanced oxidation processes.

Authors:  Cristina Afonso-Olivares; Sarah Montesdeoca-Esponda; Zoraida Sosa-Ferrera; José Juan Santana-Rodríguez
Journal:  Environ Sci Pollut Res Int       Date:  2016-08-04       Impact factor: 4.223

3.  Optimization of treating phenol from wastewater through the TiO2-catalyzed advanced oxidation process and response surface methodology.

Authors:  Camila Oliveira Guimarães; Alexandre Boscaro França; Gisella Rossana Lamas Samanamud; Eduardo Prado Baston; Renata Carolina Zanetti Lofrano; Carla Cristina Almeida Loures; Luzia Lima Rezende Naves; Fabiano Luiz Naves
Journal:  Environ Monit Assess       Date:  2019-05-05       Impact factor: 2.513

4.  Advanced oxidative processes and membrane separation for micropollutant removal from biotreated domestic wastewater.

Authors:  Larissa L S Silva; Julio C S Sales; Juacyara C Campos; Daniele M Bila; Fabiana V Fonseca
Journal:  Environ Sci Pollut Res Int       Date:  2016-08-10       Impact factor: 4.223

5.  Carbamazepine and Diclofenac Removal Double Treatment: Oxidation and Adsorption.

Authors:  Alejandro Aldeguer Esquerdo; Pedro José Varo Galvañ; Irene Sentana Gadea; Daniel Prats Rico
Journal:  Int J Environ Res Public Health       Date:  2021-07-04       Impact factor: 3.390