Evaluation of proximal protection devices during carotid artery stenting as the first choice for embolic protection.

Marius Hornung1, Stefan C Bertog, Jennifer Franke, Dani Id, Iris Grunwald, Horst Sievert.   

Abstract

AIMS: To assess the use of proximal protection devices in consecutive patients as the preferred means of cerebral embolic protection for primary carotid stenting. METHODS AND
RESULTS: This was a prospective single-centre study to evaluate the technical and clinical success of proximal protection devices as the first choice for embolic protection in symptomatic (≥50%) and asymptomatic (≥70%) carotid stenosis. Proximal protection devices were used for embolic protection in 124 consecutive patients. No patients were excluded for anatomical reasons. The GORE Flow Reversal System (W.L. Gore, Flagstaff, AZ, USA) was used in 92 patients, and the Mo.Ma Ultra device (Medtronic, Minneapolis, MN, USA) in 32 patients. Follow-up duration was 30 days. Mean age was 71±8 years. Seventy-five percent of patients were male (n=93). Twenty-six of 124 (21%) treated stenoses were symptomatic. Technical success was achieved in 122 of 124 cases (98%). Due to anatomical conditions, in two patients flow reversal could not be established. In both cases additional distal filter devices were used. Carotid stenting was successful in 124 lesions (100%). Ten patients (8.1%) had contraindications to flow reversal (three high-grade ostial stenoses of the external carotid artery, seven contralateral occlusions of the internal carotid artery) in none of whom complications occurred. There were no procedural neurologic events. Within 30 days of follow-up, one patient had an ischaemic stroke (on day 11).
CONCLUSIONS: Proximal protection is a safe method as the first choice for embolic protection. It can be used with a high rate of technical success.

Entities:  

Mesh:

Year:  2015        PMID: 25042420     DOI: 10.4244/EIJY14M07_10

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  3 in total

1.  Beating-heart Thoracoscopic Left Atrial Appendage Exclusion in a Patient with Left atrial Thrombus.

Authors:  Ali Khoynezhad
Journal:  J Atr Fibrillation       Date:  2017-12-31

Review 2.  One swallow does not a summer make but many swallows do: accumulating clinical evidence for nearly-eliminated peri-procedural and 30-day complications with mesh-covered stents transforms the carotid revascularisation field.

Authors:  Piotr Musiałek; L Nelson Hopkins; Adnan H Siddiqui
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-07-19       Impact factor: 1.426

3.  Mid-term and late results of endovascular treatment for symptomatic carotid artery stenosis under proximal protection.

Authors:  Paweł Latacz; Marian Simka; Marcin Krzanowski; Katarzyna Krzanowska; Paweł Brzegowy; Bartłomiej Łasocha; Tadeusz J Popiela
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2020-04-20       Impact factor: 1.195

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.