Literature DB >> 25042330

Mechanical properties vary for different regions of the finger extensor apparatus.

Kai Qian1, Kay Traylor1, Sang Wook Lee2, Benjamin Ellis3, Jeffrey Weiss4, Derek Kamper5.   

Abstract

The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the force distribution within the extensor apparatus, or hood, and the transmission to the phalanges is challenging, especially as knowledge of the underlying mechanical properties of the tissue is limited. We undertook quantification of some of these properties through material testing of cadaver specimens. We punched samples at specified locations from 19 extensor hood specimens. Material testing was performed to failure for each sample with a custom material testing device. Testing revealed significant differences in ultimate load, ultimate strain, thickness, and tangent modulus along the length of the extensor hood. Specifically, thickness, ultimate load, and ultimate strain were greater in the more proximal sections of the extensor hood, while the tangent modulus was greater in the more distal sections. The variations in mechanical properties within the hood may impact prediction of force transmission and, thus, should be considered when modeling the action of the extensor apparatus. Across the extensor hood, tangent modulus values were substantially smaller than values reported for other soft tissues, such as the Achilles tendon and knee ligaments, while ultimate strains were much greater. Thus, the tissue in the extensor apparatus seems to have greater elasticity, which should be modeled accordingly.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Extensor apparatus; Material properties; Soft tissue mechanics; Tensile

Mesh:

Year:  2014        PMID: 25042330      PMCID: PMC5034858          DOI: 10.1016/j.jbiomech.2014.06.035

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  31 in total

1.  THE ANATOMY OF THE EXTENSOR APPARATUS OF THE FINGERS.

Authors:  R TUBIANA; P VALENTIN
Journal:  Surg Clin North Am       Date:  1964-08       Impact factor: 2.741

2.  Optical measurements of vocal fold tensile properties: implications for phonatory mechanics.

Authors:  Jordan E Kelleher; Thomas Siegmund; Roger W Chan; Erin A Henslee
Journal:  J Biomech       Date:  2011-04-15       Impact factor: 2.712

3.  The tendon network of the fingers performs anatomical computation at a macroscopic scale.

Authors:  Francisco J Valero-Cuevas; Jae-Woong Yi; Daniel Brown; Robert V McNamara; Chandana Paul; Hood Lipson
Journal:  IEEE Trans Biomed Eng       Date:  2007-06       Impact factor: 4.538

4.  Extensor mechanism of the fingers. I. A quantitative geometric study.

Authors:  M Garcia-Elias; K N An; L Berglund; R L Linscheid; W P Cooney; E Y Chao
Journal:  J Hand Surg Am       Date:  1991-11       Impact factor: 2.230

5.  Architectural properties of the first dorsal interosseous muscle.

Authors:  Benjamin W Infantolino; John H Challis
Journal:  J Anat       Date:  2010-01-07       Impact factor: 2.610

6.  The functional significance of the long extensors and juncturae tendinum in finger extension.

Authors:  H P von Schroeder; M J Botte
Journal:  J Hand Surg Am       Date:  1993-07       Impact factor: 2.230

7.  Measurement of mechanical properties of ligament substance from a bone-ligament-bone preparation.

Authors:  S L Woo; M A Gomez; Y Seguchi; C M Endo; W H Akeson
Journal:  J Orthop Res       Date:  1983       Impact factor: 3.494

8.  Confirmation of differential loading of lateral and central fibers of the extensor tendon.

Authors:  J E Micks; J B Reswick
Journal:  J Hand Surg Am       Date:  1981-09       Impact factor: 2.230

9.  Strain variation in the components of the extensor apparatus of the finger during flexion and extension. A biomechanical study.

Authors:  S K Sarrafian; L E Kazarian; L K Topouzian; V K Sarrafian; A Siegelman
Journal:  J Bone Joint Surg Am       Date:  1970-07       Impact factor: 5.284

10.  Effects of structure and strain measurement technique on the material properties of young human tendons and fascia.

Authors:  D L Butler; E S Grood; F R Noyes; R F Zernicke; K Brackett
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

View more
  1 in total

1.  Analysis on synergistic cocontraction of extrinsic finger flexors and extensors during flexion movements: A finite element digital human hand model.

Authors:  Ying Lv; Qingli Zheng; Xiubin Chen; Chunsheng Hou; Meiwen An
Journal:  PLoS One       Date:  2022-05-11       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.