PURPOSE: To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system. METHODS: We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded. RESULTS: Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant. CONCLUSIONS: A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice.
PURPOSE: To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system. METHODS: We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded. RESULTS: Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant. CONCLUSIONS: A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice.
Authors: Tessa Drijkoningen; Robert Knoter; Emile G Coerkamp; Anton H J Koning; Steven J Rhemrev; Frank J Beeres Journal: Arch Bone Jt Surg Date: 2016-10
Authors: M Lagendijk; E L Vos; K P Ramlakhan; C Verhoef; A H J Koning; W van Lankeren; L B Koppert Journal: World J Surg Date: 2018-07 Impact factor: 3.352
Authors: Emilie Hitzerd; Igna F Reijnders; Annemarie G M G J Mulders; Anton H J Koning; Irwin K M Reiss; A H Jan Danser; Régine P M Steegers-Theunissen; Sinno H P Simons; Maria P H Koster Journal: Front Physiol Date: 2020-01-24 Impact factor: 4.566
Authors: M Lagendijk; E L Vos; A H J Koning; M G M Hunink; J P Pignol; E M L Corten; C de Monye; C H M van Deurzen; J H van Dam; W W Vrijland; C M E Contant; C Verhoef; W van Lankeren; L B Koppert Journal: BMC Cancer Date: 2017-05-17 Impact factor: 4.430
Authors: Hein Bogers; Maria S Rifouna; Titia E Cohen-Overbeek; Anton H J Koning; Sten P Willemsen; Peter J van der Spek; Régine P M Steegers-Theunissen; Niek Exalto; Eric A P Steegers Journal: J Obstet Gynaecol Res Date: 2018-11-18 Impact factor: 1.730
Authors: C S Pietersma; A G M G J Mulders; L M Moolenaar; M G M Hunink; A H J Koning; S P Willemsen; A T J I Go; E A P Steegers; M Rousian Journal: BMC Pregnancy Childbirth Date: 2020-09-07 Impact factor: 3.007
Authors: Melek Rousian; Sam Schoenmakers; Alex J Eggink; Dionne V Gootjes; Anton H J Koning; Maria P H Koster; Annemarie G M G J Mulders; Esther B Baart; Irwin K M Reiss; Joop S E Laven; Eric A P Steegers; Régine P M Steegers-Theunissen Journal: Int J Epidemiol Date: 2021-11-10 Impact factor: 7.196
Authors: Eleonora Rubini; Katinka M Snoek; Sam Schoenmakers; Sten P Willemsen; Kevin D Sinclair; Melek Rousian; Régine P M Steegers-Theunissen Journal: Nutrients Date: 2022-03-08 Impact factor: 5.717