Literature DB >> 25041997

Design and validation of a 3D virtual reality desktop system for sonographic length and volume measurements in early pregnancy evaluation.

Leonie Baken1, Isabelle M A van Gruting, Eric A P Steegers, Peter J van der Spek, Niek Exalto, Anton H J Koning.   

Abstract

PURPOSE: To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system.
METHODS: We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded.
RESULTS: Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant.
CONCLUSIONS: A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice.
© 2014 Wiley Periodicals, Inc.

Keywords:  image processing; reproducibility; three-dimensional ultrasound; virtual reality; volume measurement

Mesh:

Year:  2014        PMID: 25041997     DOI: 10.1002/jcu.22207

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  9 in total

1.  Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures.

Authors:  Tessa Drijkoningen; Robert Knoter; Emile G Coerkamp; Anton H J Koning; Steven J Rhemrev; Frank J Beeres
Journal:  Arch Bone Jt Surg       Date:  2016-10

2.  First-Trimester Crown-Rump Length and Embryonic Volume of Fetuses with Structural Congenital Abnormalities Measured in Virtual Reality: An Observational Study.

Authors:  L Baken; B Benoit; A H J Koning; P J van der Spek; E A P Steegers; N Exalto
Journal:  Biomed Res Int       Date:  2017-03-21       Impact factor: 3.411

3.  Breast and Tumour Volume Measurements in Breast Cancer Patients Using 3-D Automated Breast Volume Scanner Images.

Authors:  M Lagendijk; E L Vos; K P Ramlakhan; C Verhoef; A H J Koning; W van Lankeren; L B Koppert
Journal:  World J Surg       Date:  2018-07       Impact factor: 3.352

4.  Larger First-Trimester Placental Volumetric Parameters Are Associated With Lower Pressure and More Flow-Mediated Vasodilation of the Fetoplacental Vasculature After Delivery.

Authors:  Emilie Hitzerd; Igna F Reijnders; Annemarie G M G J Mulders; Anton H J Koning; Irwin K M Reiss; A H Jan Danser; Régine P M Steegers-Theunissen; Sinno H P Simons; Maria P H Koster
Journal:  Front Physiol       Date:  2020-01-24       Impact factor: 4.566

5.  TUmor-volume to breast-volume RAtio for improving COSmetic results in breast cancer patients (TURACOS); a randomized controlled trial.

Authors:  M Lagendijk; E L Vos; A H J Koning; M G M Hunink; J P Pignol; E M L Corten; C de Monye; C H M van Deurzen; J H van Dam; W W Vrijland; C M E Contant; C Verhoef; W van Lankeren; L B Koppert
Journal:  BMC Cancer       Date:  2017-05-17       Impact factor: 4.430

6.  First trimester physiological development of the fetal foot position using three-dimensional ultrasound in virtual reality.

Authors:  Hein Bogers; Maria S Rifouna; Titia E Cohen-Overbeek; Anton H J Koning; Sten P Willemsen; Peter J van der Spek; Régine P M Steegers-Theunissen; Niek Exalto; Eric A P Steegers
Journal:  J Obstet Gynaecol Res       Date:  2018-11-18       Impact factor: 1.730

7.  First trimester anomaly scan using virtual reality (VR FETUS study): study protocol for a randomized clinical trial.

Authors:  C S Pietersma; A G M G J Mulders; L M Moolenaar; M G M Hunink; A H J Koning; S P Willemsen; A T J I Go; E A P Steegers; M Rousian
Journal:  BMC Pregnancy Childbirth       Date:  2020-09-07       Impact factor: 3.007

8.  Cohort Profile Update: the Rotterdam Periconceptional Cohort and embryonic and fetal measurements using 3D ultrasound and virtual reality techniques.

Authors:  Melek Rousian; Sam Schoenmakers; Alex J Eggink; Dionne V Gootjes; Anton H J Koning; Maria P H Koster; Annemarie G M G J Mulders; Esther B Baart; Irwin K M Reiss; Joop S E Laven; Eric A P Steegers; Régine P M Steegers-Theunissen
Journal:  Int J Epidemiol       Date:  2021-11-10       Impact factor: 7.196

9.  First Trimester Maternal Homocysteine and Embryonic and Fetal Growth: The Rotterdam Periconception Cohort.

Authors:  Eleonora Rubini; Katinka M Snoek; Sam Schoenmakers; Sten P Willemsen; Kevin D Sinclair; Melek Rousian; Régine P M Steegers-Theunissen
Journal:  Nutrients       Date:  2022-03-08       Impact factor: 5.717

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.