Literature DB >> 25041925

Grader learning effect and reproducibility of Doppler Spectral-Domain Optical Coherence Tomography derived retinal blood flow measurements.

Kalpana Rose1, Monica Jong, Firdaus Yusof, Faryan Tayyari, Ou Tan, David Huang, Srinivas R Sadda, John G Flanagan, Christopher Hudson.   

Abstract

PURPOSE: To investigate grader learning effect and to quantify intergrader reproducibility of Doppler Spectral-Domain Optical Coherence Tomography (SD-OCT) derived retinal blood flow measurements.
METHODS: Fifteen healthy young subjects (mean age 28.44; SD 3 years) underwent Doppler SD-OCT scans of one eye using the circumpapillary double circular scan protocol of the Optovue RTVue by one of two experienced operators. One trained (i.e. having undergone certification) and one novice (i.e. preliminary training comprising five standard practice data sets) individual then graded a standardized set of scans, consisting of 15 data sets (session 1) using custom Doppler Optical Coherence Tomography of Retinal Circulation (DOCTORC) software. One week later (session 2), the novice grader underwent further training by grading an additional 15 practice data sets and then both graders subsequently regraded the original 15 data sets.
RESULTS: Measurements achieved by a novice grader during session 1 showed a trend to be higher in terms of total retinal venous blood flow (TRBF) and also to be significantly (p = 0.03) higher for venous area, compared with a trained grader. Session 2 results were not significantly different for either grader. The mean TRBF for session 2 for the trained and novice grader was 45.29 ± 9.28 μl/min and 44.39 ± 7.36 μl/min, respectively. The coefficient of repeatability (COR) of session 2 TRBF values between the trained and novice grader was 8.09 μl/min.
CONCLUSIONS: There is a grader learning effect which impacts the venous area measurements. Reproducible and repeatable retinal blood flow measurements were achieved among trained graders using DOCTORC software.
© 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Doppler optical coherence tomography; learning effect; reproducibility; total retinal blood flow

Mesh:

Year:  2014        PMID: 25041925     DOI: 10.1111/aos.12479

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  2 in total

1.  Cardiac-Gated En Face Doppler Measurement of Retinal Blood Flow Using Swept-Source Optical Coherence Tomography at 100,000 Axial Scans per Second.

Authors:  ByungKun Lee; WooJhon Choi; Jonathan J Liu; Chen D Lu; Joel S Schuman; Gadi Wollstein; Jay S Duker; Nadia K Waheed; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-04       Impact factor: 4.799

2.  Novice Reviewers Retain High Sensitivity and Specificity of Posterior Segment Disease Identification with iWellnessExam™.

Authors:  Samantha Slotnick; Catherine Awad; Sanjeev Nath; Jerome Sherman
Journal:  J Ophthalmol       Date:  2016-01-06       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.