Literature DB >> 25036413

Hybrid fixation with sublaminar polyester bands in the treatment of neuromuscular scoliosis: a comparative analysis.

Michael C Albert1, Brett C LaFleur.   

Abstract

BACKGROUND: Segmental spinal instrumentation with Luque wire fixation has been the standard treatment of neuromuscular scoliosis for >30 years. More recently, pedicle screw constructs have become the most widely utilized method of posterior spinal fixation; however, they are associated with complications such as implant malposition. We report the use of polyester bands and clamps utilized with pedicle screws in a hybrid fixation construct in the treatment of neuromuscular scoliosis.
METHODS: A retrospective review was conducted of 115 pediatric spinal deformity cases between 2008 and 2010 at a single center performed by a single surgeon. Intraoperative and postoperative complications were recorded. Radiographs were reviewed preoperatively and at the latest follow-up. A systematic review of the literature was conducted. Data from case series reporting outcomes of sublaminar wires and all-pedicle screw constructs in the treatment of neuromuscular scoliosis were compared with outcomes of the present study.
RESULTS: Twenty-nine patients with neuromuscular scoliosis who underwent segmental spinal instrumentation with a hybrid construct including sublaminar bands and pedicle screws were included. There was an average follow-up of 29 months (range, 12 to 40 mo). The average postoperative correction of coronal balance was 69% (range, 24 to 71 degrees). Sagittal balance was corrected to within 2 cm of the C7 plumbline in 97% of patients. The loss of coronal and sagittal correction at latest follow-up was 0% and 2%, respectively. There were 2 intraoperative clamp failures of the 398 implants (0.5%). There were 2 major (6.9%) and 7 minor (24%) complications in 7 patients (24% overall). These results compared favorably to previous case series of sublaminar wire and all-pedicle screw fixation techniques.
CONCLUSIONS: The polyester band technique is an excellent adjunct in the correction of spinal deformity in patients with neuromuscular scoliosis. Sublaminar bands utilized in a hybrid construct appear to be safe, can achieve corrections equivalent to all-pedicle screw constructs, and may decrease the potential complications associated with every level transpedicular fixation in the patient with a highly dysmorphic and osteoporotic spine. LEVEL OF EVIDENCE: Level IV: cohort study.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25036413     DOI: 10.1097/BPO.0000000000000235

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  5 in total

Review 1.  Sublaminar polyester bands for the correction of idiopathic and neuromuscular scoliosis.

Authors:  Federico Canavese; Antoine Samba
Journal:  Ann Transl Med       Date:  2020-01

2.  Sublaminar polyester band fixation construct in the treatment of neuromuscular scoliosis.

Authors:  S Rosenfeld; S Kenney; E Rebich
Journal:  J Child Orthop       Date:  2019-08-01       Impact factor: 1.548

3.  Autonomous lumbar spine pedicle screw planning using machine learning: A validation study.

Authors:  Kris B Siemionow; Craig W Forsthoefel; Michael P Foy; Dominik Gawel; Christian J Luciano
Journal:  J Craniovertebr Junction Spine       Date:  2021-09-08

4.  Clinical Issues in Indication, Correction, and Outcomes of the Surgery for Neuromuscular Scoliosis: Narrative Review in Pedicle Screw Era.

Authors:  Hak Sun Kim; Ji Won Kwon; Kun-Bo Park
Journal:  Neurospine       Date:  2022-01-29

5.  Double Sublaminal Band Passage Technique for Spinal Deformity Correction.

Authors:  Blake K Montgomery; Sreeharsha V Nandyala; Craig M Birch; Grant Hogue
Journal:  Cureus       Date:  2022-02-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.