Literature DB >> 25033342

Evaluation of retention forces and resistance to fatigue of attachment systems for overdentures: plastic and metal components.

Luis Carlos da Fontoura Frasca1, Paulo Roberto Castro Mattia, Daniela Maffei Botega, Elken Gomes Rivaldo.   

Abstract

PURPOSE: To compare retention forces of 3 overdenture attachment systems with metal and plastic components.
MATERIALS AND METHODS: Four samples of each system evaluated (Ball-Attachment [metal]; O-Ring, and ERA [plastic]) were prepared and underwent fatigue and retention force in a universal testing machine. Maximum retention force (N) was measured at 6 time points (from 0 to 36 months-0.5 mm/min). Two-way analysis of variance and the Tukey test were used (α = 0.05).
RESULTS: The Ball-Attachment group showed the highest retention values, statistically greater than the other systems, without differences during the trial (42.75-44.75). The ERA group had intermediate values and a statistically significant decrease during the trial (20.75-14). The lowest retention forces were found for the O-Ring group (13.75-11.75), with no statistical differences during the trial.
CONCLUSION: Retention forces are significantly affected by abutment type because the metal retainer was more retentive than plastics, possibly providing better fixation of the prosthesis in position, and more difficult to remove. After 6 months of simulation, retentiveness of both plastic components was similar. There was no fracture of any component.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25033342     DOI: 10.1097/ID.0000000000000093

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  3 in total

1.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

2.  Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial.

Authors:  M Y Sharaf; Asharaf Eskander; Mohamed Afify Afify
Journal:  Int J Dent       Date:  2022-02-28

3.  One-year prospective clinical study comparing patient satisfaction and masticatory performance of mandibular overdentures supported by one versus two implants.

Authors:  André Gustavo Paleari; Norberto Martins de Oliveira Junior; Danny Omar Mendoza Marin; Larissa Santana Rodriguez; João Neudenir Arioli Filho; Ana Carolina Pero; Marco Antonio Compagnoni
Journal:  J Appl Oral Sci       Date:  2018-10-04       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.