Literature DB >> 25033260

Surface electromyographic mapping of the orbicularis oculi muscle for real-time blink detection.

Alice Frigerio1, Paolo Cavallari2, Marta Frigeni2, Alessandra Pedrocchi3, Andrea Sarasola3, Simona Ferrante3.   

Abstract

IMPORTANCE: Facial paralysis is a life-altering condition that significantly impairs function, appearance, and communication. Facial rehabilitation via closed-loop pacing represents a potential but as yet theoretical approach to reanimation. A first critical step toward closed-loop facial pacing in cases of unilateral paralysis is the detection of healthy movements to use as a trigger to prosthetically elicit automatic artificial movements on the contralateral side of the face.
OBJECTIVES: To test and to maximize the performance of an electromyography (EMG)-based blink detection system for applications in closed-loop facial pacing. DESIGN, SETTING, AND PARTICIPANTS: Blinking was detected across the periocular region by means of multichannel surface EMG at an academic neuroengineering and medical robotics laboratory among 15 healthy volunteers. MAIN OUTCOMES AND MEASURES: Real-time blink detection was accomplished by mapping the surface of the orbicularis oculi muscle on one side of the face with a multichannel surface EMG. The biosignal from each channel was independently processed; custom software registered a blink when an amplitude-based or slope-based suprathreshold activity was detected. The experiments were performed when participants were relaxed and during the production of particular orofacial movements. An F1 score metric was used to analyze software performance in detecting blinks.
RESULTS: The maximal software performance was achieved when a blink was recorded from the superomedial orbit quadrant. At this recording location, the median F1 scores were 0.89 during spontaneous blinking, 0.82 when chewing gum, 0.80 when raising the eyebrows, and 0.70 when smiling. The overall performance of blink detection was significantly better at the superomedial quadrant (F1 score, 0.75) than at the traditionally used inferolateral quadrant (F1 score, 0.40) (P < .05). CONCLUSIONS AND RELEVANCE: Electromyographic recording represents an accurate tool to detect spontaneous blinks as part of closed-loop facial pacing systems. The early detection of blink activity may allow real-time pacing via rapid triggering of contralateral muscles. Moreover, an EMG detection system can be integrated in external devices and in implanted neuroprostheses. A potential downside to this approach involves cross talk from adjacent muscles, which can be notably reduced by recording from the superomedial quadrant of the orbicularis oculi muscle and by applying proper signal processing. LEVEL OF EVIDENCE: NA.

Entities:  

Mesh:

Year:  2014        PMID: 25033260     DOI: 10.1001/jamafacial.2014.283

Source DB:  PubMed          Journal:  JAMA Facial Plast Surg        ISSN: 2168-6076            Impact factor:   4.611


  8 in total

1.  Semi-automated Detection of Polysomnographic REM Sleep without Atonia (RSWA) in REM Sleep Behavioral Disorder.

Authors:  Iva Milerska; Vaclav Kremen; Vaclav Gerla; Erik K St Louis; Lenka Lhotska
Journal:  Biomed Signal Process Control       Date:  2019-03-07       Impact factor: 3.880

2.  Electrical Stimulation of Eye Blink in Individuals with Acute Facial Palsy: Progress toward a Bionic Blink.

Authors:  Alice Frigerio; James T Heaton; Paolo Cavallari; Chris Knox; Marc H Hohman; Tessa A Hadlock
Journal:  Plast Reconstr Surg       Date:  2015-10       Impact factor: 4.730

3.  Facial nerve electrodiagnostics for patients with facial palsy: a clinical practice guideline.

Authors:  Orlando Guntinas-Lichius; Gerd Fabian Volk; Kerry D Olsen; Antti A Mäkitie; Carl E Silver; Mark E Zafereo; Alessandra Rinaldo; Gregory W Randolph; Ricard Simo; Ashok R Shaha; Vincent Vander Poorten; Alfio Ferlito
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-04-08       Impact factor: 2.503

4.  Study on the Validity of Surface Electromyography as Assessment Tools for Facial Nerve Palsy.

Authors:  Hye-Min Ryu; Seung-Jeong Lee; Eun-Jin Park; Su-Gyeong Kim; Kyeong Han Kim; Yoo Min Choi; Jong Uk Kim; Beom Yong Song; Cheol Hong Kim; Hyun-Min Yoon; Tae-Han Yook
Journal:  J Pharmacopuncture       Date:  2018-12-31

5.  Hands-Free User Interface for VR Headsets Based on In Situ Facial Gesture Sensing.

Authors:  Jinhyuk Kim; Jaekwang Cha; Shiho Kim
Journal:  Sensors (Basel)       Date:  2020-12-16       Impact factor: 3.576

6.  The Feasibility of Surface Electromyography in Monitoring Orbicularis Oculi Recovery after Anterior Approach Levator Aponeurosis Advancement.

Authors:  Larysa Krajewska-Węglewicz; Marta Banach; Ewa Filipiak; Joanna Sempińska-Szewczyk; Piotr Skopiński; Małgorzata Dorobek
Journal:  J Clin Med       Date:  2022-01-29       Impact factor: 4.241

7.  Measurement and analysis of associated mimic muscle movements.

Authors:  Guodong Feng; Yuan Zhuang; Zhiqiang Gao
Journal:  J Otol       Date:  2015-08-01

8.  Activity Evaluation of Facial Muscles by Surface Electromyography.

Authors:  Nicolò Bertozzi; Bernardo Bianchi; Luana Salvagni; Edoardo Raposio
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-10-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.