Literature DB >> 25032943

Spinal anaesthesia with low-dose bupivacaine in marginally hyperbaric solutions for caesarean section: A randomised controlled trial.

Wen-Xi Tang1, Jian-Jun Li, Hui-Min Bu, Zhi-Jian Fu.   

Abstract

BACKGROUND: Conventional hyperbaric spinal anaesthesia solution (SAS) with 8% glucose and low-dose bupivacaine may reduce the incidence of hypotension in caesarean section compared to standard doses, and marginally hyperbaric SAS (≤0.8% glucose) can induce a lower block level and a lower incidence of hypotension in nonobstetric patients than conventional 8% glucose SAS.
OBJECTIVE: The objective of this study was to evaluate the clinical efficacy of marginally hyperbaric low-dose bupivacaine solutions used for spinal anaesthesia during caesarean section.
DESIGN: A randomised, controlled clinical trial.
SETTING: Single medical centre. PATIENTS: One hundred twenty women scheduled for elective caesarean section were randomised into four groups.
INTERVENTIONS: Caesarean section after combined spinal-epidural anaesthesia using hyperbaric preparations of low-dose SAS (7.2 mg bupivacaine and 2 μg 1.6 ml sufentanil in one of the following: 8%, 0.8%, 0.5% or 0.33% glucose solution. MAIN OUTCOME MEASURES: The dermatomal sensory block and degree of motor block of the lower extremities and adverse effects of anaesthesia were recorded.
RESULTS: The maximum cephalad sensory block level and the incidence of hypotension decreased as the density of SAS fell (T1, T2, T4 and T6, P < 0.001; 48.3, 30, 13.3 and 10.3%, P = 0.003). The incidence of shivering reduced with decreasing density of SAS (P < 0.05). There was no significant difference in the quality of anaesthesia (efficacy of motor block and sensory block) between the groups (P > 0.05).
CONCLUSION: Compared with conventional 8% glucose hyperbaric SAS, marginally hyperbaric (0.5 or 0.33% glucose) low-dose bupivacaine solutions led to a significantly lower height of cephalad spread and incidence of hypotension with no impact on the efficacy of spinal anaesthesia for caesarean section.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25032943     DOI: 10.1097/EJA.0000000000000112

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  2 in total

1.  Techniques for preventing hypotension during spinal anaesthesia for caesarean section.

Authors:  Cheryl Chooi; Julia J Cox; Richard S Lumb; Philippa Middleton; Mark Chemali; Richard S Emmett; Scott W Simmons; Allan M Cyna
Journal:  Cochrane Database Syst Rev       Date:  2020-07-01

2.  The relationship between core temperature and perioperative shivering during caesarean section under intrathecal anesthesia with bupivacaine and ropivacaine: a randomized controlled study.

Authors:  Guangju Feng; Yu Wang; Jiehua Feng; Xiaomin Luo; Chaoyang Li; Shanglong Yao
Journal:  J Anesth       Date:  2021-09-02       Impact factor: 2.078

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.