Literature DB >> 25032772

Zirconia dental implants: a clinical, radiographic, and microbiologic evaluation up to 3 years.

Felix Brüll, Arie Jan van Winkelhoff, Marco S Cune.   

Abstract

PURPOSE: To retrospectively evaluate the clinical performance of zirconia endosseous implants.
MATERIALS AND METHODS: Partially edentulous patients with adequate bone volume to fit yttria tetragonal zirconia polycrystal (Y-TZP) implants at least 3.5 mm wide and 8.0 mm long were included. Full-mouth probing pocket depth (PPDs) and percentage bleeding on probing (BOP) scores around teeth and implant(s) were assessed and compared. Marginal bone loss/gain relative to baseline was measured on intraoral radiographs, and the prevalence and quantities of seven periodontal bacteria were assessed around implants and teeth in the same patient.
RESULTS: Seventy-four consecutively treated patients with 121 zirconia implants (66 two-piece implants and 55 one-piece implants) were clinically evaluated after a mean observation period of 18 months. Three implants had failed and had been removed, for a cumulative implant survival rate of 96.5% (± 2.0%) after 3 years. The 118 surviving implants demonstrated healthy mucosal conditions, with low mean PPDs (1.8 ± 0.4 mm) and mean BOP scores (4.1% ± 4.2%). PPD and BOP were statistically significantly lower around implants than around teeth. BOP and PPD around implants and teeth were significantly correlated. Stable marginal bone levels were observed (mean bone loss of 0.1 ± 0.6 mm after 3 years). The frequency of isolation of all marker bacteria was similar at tooth and implant sites.
CONCLUSION: Zirconia endosseous implants can achieve a 3-year implant survival rate in partially edentulous patients, similar to that of titanium implants, with healthy and stable soft and hard tissues.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25032772     DOI: 10.11607/jomi.3293

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

2.  Zirconia Implants in Esthetic Areas: 4-Year Follow-Up Evaluation Study.

Authors:  Andrea Enrico Borgonovo; Rachele Censi; Virna Vavassori; Oscar Arnaboldi; Carlo Maiorana; Dino Re
Journal:  Int J Dent       Date:  2015-06-01

3.  Implant Supported Fixed Dental Prostheses Using a New Monotype Zirconia Implant-A Case Report.

Authors:  Stefan Roehling; Georges Ghazal; Thomas Borer; Florian Thieringer; Michael Gahlert
Journal:  Dent J (Basel)       Date:  2015-09-17

Review 4.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

5.  Biocompatibility of Yttria-Tetragonal Zirconia Polycrystal Seeded with Human Adipose Derived Mesenchymal Stem Cell.

Authors:  Arif Rachman; Fedik A Rantam; Indra Bachtiar; Fatchiyah Fatchiyah; Lukman Hakim; Indri L Putri; Latief Mooduto
Journal:  Acta Inform Med       Date:  2018-12

6.  Direct-Deposited Graphene Oxide on Dental Implants for Antimicrobial Activities and Osteogenesis.

Authors:  WooHyung Jang; Hee-Seon Kim; Khurshed Alam; Min-Kyung Ji; Hoon-Sung Cho; Hyun-Pil Lim
Journal:  Int J Nanomedicine       Date:  2021-08-24

7.  Clinical and radiographic success of injection-molded 2-piece zirconia implants submitted to immediate loading: A 12-month report of two cases.

Authors:  Geninho Thomé; Jean Uhlendorf; Camila Pereira Vianna; Waleska Caldas; Sergio Rocha Bernardes; Larissa Carvalho Trojan
Journal:  Clin Case Rep       Date:  2021-12-04

Review 8.  A systematic review of the clinical survival of zirconia implants.

Authors:  Dena Hashim; Norbert Cionca; Delphine S Courvoisier; Andrea Mombelli
Journal:  Clin Oral Investig       Date:  2016-05-24       Impact factor: 3.573

9.  Comparative study of new bone formation capability of zirconia bone graft material in rabbit calvarial.

Authors:  Ik-Jung Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.