Literature DB >> 25032767

Accuracy of impressions of multiple implants in the edentulous arch: a systematic review.

Mirza Rustum Baig.   

Abstract

PURPOSE: Because there is a paucity of clear-cut evidence regarding which materials and techniques are most accurate for complete-arch, multiple-implant impressions, the current study sought to analyze the data and draw useful conclusions based on the evidence for application in clinical practice.
MATERIALS AND METHODS: Relevant studies published between 1990 and December 2012 were included in the review. The articles were located through PubMed and manually through reviewing references in the literature. Papers examining implant impression accuracy in completely edentulous arches (three or more implants) were included. Clinical case reports, technique articles, abstracts, and review papers were excluded.
RESULTS: One of the 34 studies selected for evaluation was clinical; the remaining 33 were in vitro investigations. Ten studies compared polyvinyl siloxane (PVS) and polyether (PE); eight found that these were statistically equal in terms of impression accuracy. The splint effect was examined by 24 studies; 10 failed to observe any differences between splinted and nonsplinted impressions, whereas 7 (> 25%) showed that the splinted technique was better than the nonsplinted technique. Thirteen studies investigated the differences between pickup and transfer impression techniques; six favored pickup over transfer, and five found insignificant differences between the techniques. The effect of nonparallel implants on edentulous multiple-implant impression accuracy was examined by only two studies. Significant differences in accuracy were observed for 15 degrees of angulation.
CONCLUSION: Most of the evidence supports PVS and PE as the most accurate impression materials for edentulous multiple-implant situations, with no clear advantage of either. Conflicting evidence exists regarding the most accurate impression technique (splinted/nonsplinted, pickup/transfer), and no clear recommendation can be made. Inadequate research exists regarding several other factors that might affect edentulous implant impression accuracy. There is a lack of clinical research to support in vitro findings.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25032767     DOI: 10.11607/jomi.3233

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure.

Authors:  Maria Menini; Paolo Setti; Francesco Pera; Paolo Pera; Paolo Pesce
Journal:  Clin Oral Investig       Date:  2017-09-30       Impact factor: 3.573

2.  Effect of technique and impression material on the vertical misfit of a screw-retained, three-unit implant bridge: An in vitro study.

Authors:  Hamidreza Rajati Haghi; Masoud Shiehzadeh; Mohammadreza Nakhaei; Fatemeh Ahrary; Saeid Sabzevari
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

3.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

4.  Comparison of the Accuracy of Fixture-Level Implant Impression Making with Different Splinting Techniques.

Authors:  Mehrdad Nateghi; Ramin Negahdari; Sahar Molaei; Ali Barzegar; Sepideh Bohlouli
Journal:  Int J Dent       Date:  2021-10-14

5.  Three-dimensional accuracy of different impression techniques for dental implants.

Authors:  Mohammadreza Nakhaei; Azam S Madani; Azizollah Moraditalab; Hamidreza Rajati Haghi
Journal:  Dent Res J (Isfahan)       Date:  2015 Sep-Oct

Review 6.  Advancements in Soft-Tissue Prosthetics Part A: The Art of Imitating Life.

Authors:  Rena L J Cruz; Maureen T Ross; Sean K Powell; Maria A Woodruff
Journal:  Front Bioeng Biotechnol       Date:  2020-03-31

7.  A prospective clinical study on implant impression accuracy.

Authors:  Motaz Osman; Hassan Ziada; Ahmed Suliman; Neamat Hassan Abubakr
Journal:  Int J Implant Dent       Date:  2019-11-19

8.  Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study.

Authors:  Agne Gedrimiene; Rimas Adaskevicius; Vygandas Rutkunas
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

9.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

10.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.