Literature DB >> 25032763

Accuracy of implant impressions for partially and completely edentulous patients: a systematic review.

Panos Papaspyridakos, Chun-Jung Chen, German O Gallucci, Asterios Doukoudakis, Hans-Peter Weber, Vasilios Chronopoulos.   

Abstract

PURPOSE: To compare the accuracy of digital and conventional impression techniques for partially and completely edentulous patients and to determine the effect of different variables on the accuracy outcomes.
MATERIALS AND METHODS: An electronic and manual search was conducted to identify studies reporting on the accuracy of implant impressions. Pooled data were descriptively analyzed. Factors affecting the accuracy were identified, and their impact on accuracy outcomes was assessed.
RESULTS: The 76 studies that fulfilled the inclusion criteria featured 4 clinical studies and 72 in vitro studies. Studies were grouped according to edentulism; 41 reported on completely edentulous and 35 on partially edentulous patients. For completely edentulous patients, most in vitro studies and all three clinical studies demonstrated better accuracy with the splinted vs the nonsplinted technique (15 studies, splint; 1, nonsplint; 9, no difference). One clinical study and half of the in vitro studies reported better accuracy with the open-tray vs the closed-tray technique (10 studies, open-tray; 1, closed-tray; 10, no difference). For partially edentulous patients, one clinical study and most in vitro studies showed better accuracy with the splinted vs the nonsplinted technique (8 studies, splint; 2, nonsplint; 3, no difference). The majority of in vitro studies showed better accuracy with the open-tray vs the closed-tray technique (10 studies, open-tray; 1, closed-tray; 7, no difference), but the only clinical study reported no difference.
CONCLUSION: The splinted impression technique is more accurate for both partially and completely edentulous patients. The open-tray technique is more accurate than the closed-tray for completely edentulous patients, but for partially edentulous patients there seems to be no difference. The impression material (polyether or polyvinylsiloxane) has no effect on the accuracy. The implant angulation affects the accuracy of implant impressions, while there are insufficient studies for the effect of implant connection type. Further accuracy studies are needed regarding digital implant impressions.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25032763     DOI: 10.11607/jomi.3625

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  22 in total

Review 1.  Factors affecting the complexity of dental implant restoration - what is the current evidence and guidance?

Authors:  S P Wright; J Hayden; J A Lynd; K Walker-Finch; J Willett; C Ucer; S D Speechley
Journal:  Br Dent J       Date:  2016-11-18       Impact factor: 1.626

Review 2.  Screw-retained crown restorations of single implants: A step-by-step clinical guide.

Authors:  Mohammad Assaf; Alaa' Z Abu Gharbyeh
Journal:  Eur J Dent       Date:  2014-10

Review 3.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

4.  Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study.

Authors:  Mario Imburgia; Silvia Logozzo; Uli Hauschild; Giovanni Veronesi; Carlo Mangano; Francesco Guido Mangano
Journal:  BMC Oral Health       Date:  2017-06-02       Impact factor: 2.757

5.  In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

Authors:  Sonam Gupta; Aparna Ichalangod Narayan; Dhanasekar Balakrishnan
Journal:  Int J Dent       Date:  2017-02-27

6.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01

7.  Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type.

Authors:  Marzieh Alikhasi; Hakime Siadat; Alireza Nasirpour; Mahya Hasanzade
Journal:  Int J Dent       Date:  2018-06-04

8.  Accuracy of Implant Casts Generated with Conventional and Digital Impressions-An In Vitro Study.

Authors:  Paulo Ribeiro; Mariano Herrero-Climent; Carmen Díaz-Castro; José Vicente Ríos-Santos; Roberto Padrós; Javier Gil Mur; Carlos Falcão
Journal:  Int J Environ Res Public Health       Date:  2018-07-27       Impact factor: 3.390

9.  A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques.

Authors:  Rupali Patil; Pankaj Kadam; Chetan Oswal; Seema Patil; Shweta Jajoo; Arati Gachake
Journal:  J Int Soc Prev Community Dent       Date:  2016 Mar-Apr

10.  Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study.

Authors:  G Parameshwari; B Chittaranjan; N Sudhir; C-K Anulekha-Avinash; M Taruna; M Ramureddy
Journal:  J Clin Exp Dent       Date:  2018-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.