Literature DB >> 25031920

Predictable biomechanics and implications of implant crest module: a clinical note.

V Khanna1, G Khanna2, A Bansal1, R Malik3.   

Abstract

Entities:  

Year:  2014        PMID: 25031920      PMCID: PMC4083716          DOI: 10.4103/2141-9248.131735

Source DB:  PubMed          Journal:  Ann Med Health Sci Res        ISSN: 2141-9248


× No keyword cloud information.
Sir Biomechanical considerations in implant dentistry to a large extent follow simple mechanical rates, based on leverage principles and the implants initial stabilization. That is why; the sound knowledge of biomechanics will truly minimize the overload situations which control the long-term success of dental implants. Marginal bone loss around implants may pose a threat to its long-term survival. Some of the major factors constituting marginal bone loss are: (1) Designing sophistication and sensitivity of implant assembly; (2) infectious process; (3) excessive loading conditions; (4) the location, shape, and size of the implant-abutment microgap and its microbial contamination; (5) micro-movements of the implant and prosthetic components; (6) repeated screwing and unscrewing; and (7) traumatic surgical technique.[1] Implant crest module is one of the segments of a two-piece dental implant that is designed to hold the prosthetic components and to create a transition zone to the load bearing implant body.[2] Its design, position in relation to the alveolar crest, and an abutment implant interface makes us believe that, it has a major role in integration to both hard and soft tissues. In other words, the crest module of an implant body is characterized as a region of highly concentrated mechanical stress [Figure 1]. This region of the implant is not ideally designed for load bearing, as evidenced by bone loss as a common occurrence regardless of design or technique. Many studies in the literature have shown that mean marginal bone loss of adjacent teeth recorded over the average time of examination (16 months) was 0.97 (1.46) mm and observed at upper lateral incisors facing a fixture in the canine or central incisor regions. In fact, bone loss has been observed so often, many implant crest modules are designed to reduce plaque accumulation once bone loss has occurred.[34] A smooth, parallel-sided crest module will result in shear stresses in this region, making maintenance of bone very difficult. An angled crest module of more than 20°, with a surface texture that increases bone contact, will impose a slight beneficial compressive component to the contiguous bone and decrease the risk of alveolar bone loss.[1]
Figure 1

The crest module design can transmit different types of force to bone. (a) A polished collar as well as a straight crest module design transmits shear force however, (b) A rough surface on an angled collar may pose some compressive force to underlying bone

The crest module design can transmit different types of force to bone. (a) A polished collar as well as a straight crest module design transmits shear force however, (b) A rough surface on an angled collar may pose some compressive force to underlying bone Usually, the crest module of an implant ought to be faintly larger than the outer thread of implant diameter. The ideal seal created by the larger crest module also provides for greater initial stability of the implant following placement, especially in softer unprepared bone, as it compresses the region.[56] The larger diameter also increases surface area, which contributes to decrease in stress at the crestal region compared with crest modules of smaller diameter.[7] A polished collar of minimum height should be designed on the superior portion of the crest module just below the prosthetic platform. A biologic width of 0.5 mm has been reported apical to the abutment-to-implant connection. A 0.5 mm collar length provides for a desirable smooth surface close to the peri-gingival area, while preserving the biomechanical performance of the remaining portion of the crest module. Bone is subjected to unnecessary and excessive shear loading in implants characterized by a longer polished collar. Significant loss of crestal bone has been reported for implants with larger machined (smooth) corona regions.[8910] This bone loss is attributed to the lack of effective mechanical loading between the machined coronal region of the implant and the surrounding bone. Such clinical dilemma is abridged by a biomechanical design that could minimize the shear collar surface area. Nevertheless, it is quite obvious that the crest module design can transmit different types of forces onto the bone, which depends upon its surface texture and shape. A polished collar and a straight crest module design transmit shear force, whereas a rough surface with an angled collar transmits beneficial compressive force to the bone.[11] Furthermore, it has now been a universal clinical observation that bone is often lost to the first thread, regardless of the manufacturer type or design, after loading. Bone grows above the threads during healing, but after prosthesis loading the bone loss is often observed. The bone loss often stops at the first thread because, the first thread changes the shear forces of the crest module to a component of compressive force in which bone is strongest.
  8 in total

Review 1.  Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis.

Authors:  Momen A Atieh; Hadeel M Ibrahim; Ahmad H Atieh
Journal:  J Periodontol       Date:  2010-10       Impact factor: 6.993

Review 2.  A positive correlation between occlusal trauma and peri-implant bone loss: literature support.

Authors:  Carl E Misch; Jon B Suzuki; Francine M Misch-Dietsh; Martha W Bidez
Journal:  Implant Dent       Date:  2005-06       Impact factor: 2.454

3.  Subcrestal placement of two-part implants.

Authors:  Maria Welander; Ingemar Abrahamsson; Tord Berglundh
Journal:  Clin Oral Implants Res       Date:  2009-03       Impact factor: 5.977

4.  Response to "On crestal/marginal bone loss around dental implants".

Authors:  Stuart J Froum; Paul S Rosen; Donald S Clem
Journal:  Int J Periodontics Restorative Dent       Date:  2013 Jul-Aug       Impact factor: 1.840

Review 5.  Current interpretations of the osseointegrated response: clinical significance.

Authors:  T Albrektsson; G A Zarb
Journal:  Int J Prosthodont       Date:  1993 Mar-Apr       Impact factor: 1.681

6.  Platform switching and bone platform switching.

Authors:  Francesco Carinci; Giorgio Brunelli; Matteo Danza
Journal:  J Oral Implantol       Date:  2009       Impact factor: 1.779

Review 7.  Implant crest module: a review of biomechanical considerations.

Authors:  I N Aparna; B Dhanasekar; D Lingeshwar; Lokendra Gupta
Journal:  Indian J Dent Res       Date:  2012 Mar-Apr

Review 8.  Reasons for marginal bone loss around oral implants.

Authors:  Jie Qian; Ann Wennerberg; Tomas Albrektsson
Journal:  Clin Implant Dent Relat Res       Date:  2012-11-30       Impact factor: 3.932

  8 in total
  1 in total

1.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.