Measurement-based model of a wide-bore CT scanner for Monte Carlo dosimetric calculations with GMCTdospp software.

Witold Skrzyński1.   

Abstract

The aim of this work was to create a model of a wide-bore Siemens Somatom Sensation Open CT scanner for use with GMCTdospp, which is an EGSnrc-based software tool dedicated for Monte Carlo calculations of dose in CT examinations. The method was based on matching spectrum and filtration to half value layer and dose profile, and thus was similar to the method of Turner et al. (Med. Phys. 36, pp. 2154-2164). Input data on unfiltered beam spectra were taken from two sources: the TASMIP model and IPEM Report 78. Two sources of HVL data were also used, namely measurements and documentation. Dose profile along the fan-beam was measured with Gafchromic RTQA-1010 (QA+) film. Two-component model of filtration was assumed: bow-tie filter made of aluminum with 0.5 mm thickness on central axis, and flat filter made of one of four materials: aluminum, graphite, lead, or titanium. Good agreement between calculations and measurements was obtained for models based on the measured values of HVL. Doses calculated with GMCTdospp differed from the doses measured with pencil ion chamber placed in PMMA phantom by less than 5%, and root mean square difference for four tube potentials and three positions in the phantom did not exceed 2.5%. The differences for models based on HVL values from documentation exceeded 10%. Models based on TASMIP spectra and IPEM78 spectra performed equally well.
Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CT; GMCTdospp; Monte Carlo dose simulations; Radiation dose

Mesh:

Year:  2014        PMID: 25028213     DOI: 10.1016/j.ejmp.2014.06.045

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

1.  Technical Note: Measurement of bow tie profiles in CT scanners using radiochromic film.

Authors:  Bruce R Whiting; Andreea C Dohatcu; Joshua D Evans; David G Politte; Jeffrey F Williamson
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

2.  Effect of ROI filtering in 3D cone-beam rotational angiography on organ dose and effective dose in cerebral investigations.

Authors:  Fabian Göpfert; Ralph Schmidt; Jörg Wulff; Klemens Zink
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.