Literature DB >> 25023661

Patellofemoral arthroplasty influences tibiofemoral kinematics: the effect of patellar thickness.

Hilde Vandenneucker1, Luc Labey, Jan Victor, Jos Vander Sloten, Kaat Desloovere, Johan Bellemans.   

Abstract

PURPOSE: Although controversy still remains, isolated patellofemoral arthroplasty recently gained in popularity as a treatment option for patellofemoral osteoarthritis. It has compared to total knee arthroplasty the advantage of preserving the tibiofemoral articulation, which in theory would allow the preservation of natural tibiofemoral kinematics. Today, however, no data exist to support this assumption. This study was therefore performed in order to investigate the effect of isolated patellofemoral arthroplasty on the native three-dimensional tibiofemoral kinematic behaviour and whether a change in patellar thickness would have an influence.
METHODS: Six fresh-frozen cadavers were fixed on a custom-made mechanical knee rig. Full 3D kinematics was analysed during passive flexion-extension cycles, open chain extension, with and without mechanical resistance, as well as deep knee squats, using infrared motion capture cameras and retroflective markers. Measurements were taken for the native knee and after prosthetic trochlear resurfacing with and without patellar resurfacing in three different patellar thicknesses.
RESULTS: Compared to the natural knee, patellofemoral arthroplasty resulted in significant changes in tibiofemoral kinematics, which were most pronounced in the most loaded motor tasks. Increased internal tibial rotation was noted in the mid- and high flexion ranges, reaching at 120° of flexion a mean difference of 4.5°±4.3° (p<0.0001) during squat motion, over the whole flexion range during open chain motion and in deeper flexion beyond 50° (mean at 70°, 1.9°±3.7°) during resisted open chain. During squats, also, a more posterior translation of the lateral femoral condyle was observed. The effect was accentuated in case of patella overstuffing, whereas kinematics was closer to normal with patellar thinning.
CONCLUSION: Isolated patellofemoral arthroplasty alters natural tibiofemoral kinematics, and the effects become more pronounced in case of increased patellar thickness. Therefore, it might be recommended to aim for a slight over-resection of patellar bone if sufficient bone stock is available.

Entities:  

Mesh:

Year:  2014        PMID: 25023661     DOI: 10.1007/s00167-014-3160-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  28 in total

Review 1.  Biomechanics of patellofemoral joint prostheses.

Authors:  Andrew A Amis; Wongwit Senavongse; Peter Darcy
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

Review 2.  Indications, contraindications, and pitfalls of patellofemoral arthroplasty.

Authors:  Wayne B Leadbetter; Thorsten M Seyler; Phillip S Ragland; Michael A Mont
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

3.  How precise can bony landmarks be determined on a CT scan of the knee?

Authors:  J Victor; D Van Doninck; L Labey; B Innocenti; P M Parizel; J Bellemans
Journal:  Knee       Date:  2009-02-05       Impact factor: 2.199

4.  Patellofemoral arthroplasty: the third compartment.

Authors:  Paul A Lotke; Jess H Lonner; Charles L Nelson
Journal:  J Arthroplasty       Date:  2005-06       Impact factor: 4.757

5.  Prospective clinical and radiological two-year results after patellofemoral arthroplasty using an implant with an asymmetric trochlea design.

Authors:  Knut Beitzel; Philip B Schöttle; Matthias Cotic; Vyas Dharmesh; Andreas B Imhoff
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-01       Impact factor: 4.342

6.  Patellofemoral arthroplasty. A 2- to 18-year followup study.

Authors:  J B Krajca-Radcliffe; T P Coker
Journal:  Clin Orthop Relat Res       Date:  1996-09       Impact factor: 4.176

7.  Treatment of patello-femoral arthritis using the Lubinus patello-femoral arthroplasty: a retrospective review.

Authors:  A M Smith; W R C Peckett; P A Butler-Manuel; K M Venu; J C d'Arcy
Journal:  Knee       Date:  2002-02       Impact factor: 2.199

8.  Patellofemoral arthroplasty: an update.

Authors:  Jean-Noël A Argenson; Xavier Flecher; Sebastien Parratte; Jean-Manuel Aubaniac
Journal:  Clin Orthop Relat Res       Date:  2005-11       Impact factor: 4.176

9.  Early results with a total patellofemoral joint replacement arthroplasty prosthesis.

Authors:  Alan C Merchant
Journal:  J Arthroplasty       Date:  2004-10       Impact factor: 4.757

10.  The influence of muscle load on tibiofemoral knee kinematics.

Authors:  Jan Victor; Luc Labey; Pius Wong; Bernardo Innocenti; Johan Bellemans
Journal:  J Orthop Res       Date:  2010-04       Impact factor: 3.494

View more
  8 in total

1.  Upright weight-bearing CT of the knee during flexion: changes of the patellofemoral and tibiofemoral articulations between 0° and 120°.

Authors:  Anna Hirschmann; Florian M Buck; Ramin Herschel; Christian W A Pfirrmann; Sandro F Fucentese
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-04       Impact factor: 4.342

2.  The correlation between femoral sulcus morphology and osteoarthritic changes in the patello-femoral joint.

Authors:  Takanori Iriuchishima; Keinosuke Ryu; Tohru Murakami; Hiroshi Yorifuji
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-06-04       Impact factor: 4.342

3.  Three-dimensional patellar tendon fibre kinematics in navigated TKA with and without patellar resurfacing.

Authors:  C Belvedere; A Ensini; M d'Amato; P Barbadoro; A Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-13       Impact factor: 4.342

4.  Kinematics of a bicruciate-retaining total knee arthroplasty.

Authors:  Thomas J Heyse; Joshua Slane; Geert Peersman; Margo Dirckx; Arne van de Vyver; Philipp Dworschak; Susanne Fuchs-Winkelmann; Lennart Scheys
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-01-11       Impact factor: 4.342

5.  Influence of tibial rotation in total knee arthroplasty on knee kinematics and retropatellar pressure: an in vitro study.

Authors:  Arnd Steinbrück; Christian Schröder; Matthias Woiczinski; Tatjana Müller; Peter E Müller; Volkmar Jansson; Andreas Fottner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-11       Impact factor: 4.342

6.  Does patellofemoral geometry in TKA affect patellar position in mid-flexion?

Authors:  Mo Saffarini; Stefano Zaffagnini; Simone Bignozzi; Francesca Colle; Maurilio Marcacci; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-13       Impact factor: 4.342

7.  Changes in sagittal component alignment alters patellar kinematics in TKA: an in vitro study.

Authors:  Armin Keshmiri; Hans Robert Springorum; Clemens Baier; Florian Zeman; Joachim Grifka; Günther Maderbacher
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-28       Impact factor: 4.342

8.  High mid-term revision rate after treatment of large, full-thickness cartilage lesions and OA in the patellofemoral joint using a large inlay resurfacing prosthesis: HemiCAP-Wave®.

Authors:  Jens Ole Laursen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-06       Impact factor: 4.342

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.