Literature DB >> 25023564

An estimation method for improved extraction of the decay curve signal from CPMG-like measurements with a unilateral scanner.

Elad Bergman1, Arie Yeredor2, Uri Nevo3.   

Abstract

Unilateral NMR devices are valuable tools used to study non-invasively arbitrarily-sized objects. They have been utilized in various applications, including non-destructive testing and well logging. However, measurements with such scanners are characterized by a low sensitivity, which is mainly the result of the low and inhomogeneous magnetic field B0. The resulting poor signal to noise ratio (SNR) is a prominent limitation, as it deteriorates the accuracy of data analysis. Improving the SNR is typically done by the use of averaging repetitions that result in too long scan times. This work presents a statistical signal-processing method that can improve the sensitivity of a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence for measurements of transverse-relaxation with unilateral scanners. The method improves the extraction of the decay curve from the noisy data. This is done by exploiting the redundancy in the acquired signal and by the use of the noise characteristics, which are both incorporated into a weighted least-squares estimation approach. This technique is especially effective in applications where RF shielding is not in use, and the measurements are corrupted by dominant non-white noise. The method performance was evaluated with a series of CPMG-like measurements applied on two samples. Decay curves were extracted from each measurement with the proposed method and were compared to a conventional extraction of the decay curve. All measurements showed a significant improvement in the accuracy of estimation of the decaying signal. Thus, the improvement in the sensitivity can be translated into a reduction in the acquisition times (by reducing the need in averaging repetitions) or to a more accurate fitting process of the traverse relaxation distribution.
Copyright © 2014 Elsevier Inc. All rights reserved.

Keywords:  CPMG; Estimation; Inhomogeneity; Inhomogeneous; Least squares; NMR MOUSE; Portable NMR; Single-sided NMR; Stray field; Transverse relaxation; Unilateral NMR

Year:  2014        PMID: 25023564     DOI: 10.1016/j.jmr.2014.05.003

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  2 in total

1.  Monitoring of Cellular Changes in the Bone Marrow following PTH(1-34) Treatment of OVX Rats Using a Portable Stray-Field NMR Scanner.

Authors:  Inbar Hillel; Itzhak Binderman; Yifat Sarda; Uri Nevo
Journal:  J Osteoporos       Date:  2017-05-30

2.  The Novel Design of a Single-Sided MRI Probe for Assessing Burn Depth.

Authors:  Zhonghua He; Wei He; Jiamin Wu; Zheng Xu
Journal:  Sensors (Basel)       Date:  2017-03-06       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.