Literature DB >> 25017301

Viscoelastic characterisation of pig liver in unconfined compression.

G Mattei1, A Tirella2, G Gallone3, A Ahluwalia2.   

Abstract

Understanding and modelling liver biomechanics represents a significant challenge due to the complex nature of this organ. Unfortunately, there is no consensus on liver viscoelastic properties, and results are strongly dependent on sample type and status, adopted testing method, and testing conditions. Standard force-triggered tests (e.g. step response or dynamic mechanical tests) necessitate an initial contact between sample and testing apparatus, which may result in significant pre-stress to very soft and highly hydrated samples. In a previous study we proposed the epsilon dot method (ε̇M): a testing and analysis framework to address the drawbacks of standard mechanical tests. Focusing on ex-vivo unconfined bulk compressive tests, here we use both the ε̇M and dynamic mechanical analysis (DMA) to derive liver viscoelastic parameters in the region of small strains or the linear viscoelastic region (LVR). As liver samples were visibly deteriorated at the end of frequency sweep tests, a modified approach was adopted to reduce DMA testing times. This approach, termed step-reconstructed DMA (SRDMA), is based on dynamic measurements around specific frequencies and then reconstruction of liver behaviour in the entire frequency range of interest. The instantaneous elastic modulus obtained from SRDMA tests (2.65 ± 0.30 kPa) was significantly higher than that obtained with the ε̇M (2.04 ± 0.01 kPa). We show that the overestimation of stiffness is due to data acquisition in a local rather than an absolute LVR, highlighting the importance of using a rapid and zero pre-stress approach to characterise very soft and highly hydrated biological tissues.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dynamic mechanical analysis; Liver; Soft tissues; Strain rate; Viscoelastic models

Mesh:

Year:  2014        PMID: 25017301     DOI: 10.1016/j.jbiomech.2014.05.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  11 in total

1.  Bioinspired liver scaffold design criteria.

Authors:  Giorgio Mattei; Chiara Magliaro; Andrea Pirone; Arti Ahluwalia
Journal:  Organogenesis       Date:  2018-08-29       Impact factor: 2.500

2.  Repeated High Rate Facet Capsular Stretch at Strains That are Below the Pain Threshold Induces Pain and Spinal Inflammation With Decreased Ligament Strength in the Rat.

Authors:  Sonia Kartha; Ben A Bulka; Nick S Stiansen; Harrison R Troche; Beth A Winkelstein
Journal:  J Biomech Eng       Date:  2018-08-01       Impact factor: 2.097

3.  Profile analysis of hepatic porcine and murine brain tissue slices obtained with a vibratome.

Authors:  G Mattei; I Cristiani; C Magliaro; A Ahluwalia
Journal:  PeerJ       Date:  2015-04-30       Impact factor: 2.984

4.  On the adhesion-cohesion balance and oxygen consumption characteristics of liver organoids.

Authors:  Giorgio Mattei; Chiara Magliaro; Serena Giusti; Sarada Devi Ramachandran; Stefan Heinz; Joris Braspenning; Arti Ahluwalia
Journal:  PLoS One       Date:  2017-03-07       Impact factor: 3.240

5.  Functionalized Enzyme-Responsive Biomaterials to Model Tissue Stiffening in vitro.

Authors:  Annalisa Tirella; Giorgio Mattei; Margherita La Marca; Arti Ahluwalia; Nicola Tirelli
Journal:  Front Bioeng Biotechnol       Date:  2020-04-08

Review 6.  Accounting for Material Changes in Decellularized Tissue with Underutilized Methodologies.

Authors:  Ryan A Behmer Hansen; Xinming Wang; Gitanjali Kaw; Valinteshley Pierre; Samuel E Senyo
Journal:  Biomed Res Int       Date:  2021-05-31       Impact factor: 3.246

7.  Micro-Mechanical Viscoelastic Properties of Crosslinked Hydrogels Using the Nano-Epsilon Dot Method.

Authors:  Giorgio Mattei; Ludovica Cacopardo; Arti Ahluwalia
Journal:  Materials (Basel)       Date:  2017-08-02       Impact factor: 3.623

8.  Comparison of frequency and strain-rate domain mechanical characterization.

Authors:  Luca Bartolini; Davide Iannuzzi; Giorgio Mattei
Journal:  Sci Rep       Date:  2018-09-12       Impact factor: 4.379

9.  Engineering Gels with Time-Evolving Viscoelasticity.

Authors:  Giorgio Mattei; Ludovica Cacopardo; And Arti Ahluwalia
Journal:  Materials (Basel)       Date:  2020-01-16       Impact factor: 3.623

10.  Soft-Tissue-Mimicking Using Hydrogels for the Development of Phantoms.

Authors:  Aitor Tejo-Otero; Felip Fenollosa-Artés; Isabel Achaerandio; Sergi Rey-Vinolas; Irene Buj-Corral; Miguel Ángel Mateos-Timoneda; Elisabeth Engel
Journal:  Gels       Date:  2022-01-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.