Literature DB >> 25015201

Determination of internal target volume for radiation treatment planning of esophageal cancer by using 4-dimensional computed tomography (4DCT).

Xiaojian Chen1, Haijun Lu2, An Tai1, Candice Johnstone1, Elizabeth Gore1, X Allen Li3.   

Abstract

PURPOSE: To determine an efficient strategy for the generation of the internal target volume (ITV) for radiation treatment planning for esophageal cancer using 4-dimensional computed tomography (4DCT). METHODS AND MATERIALS: 4DCT sets acquired for 20 patients with esophageal carcinoma were analyzed. Each of the 4DCT sets was binned into 10 respiratory phases. For each patient, the gross tumor volume (GTV) was delineated on the 4DCT set at each phase. Various strategies to derive ITV were explored, including the volume from the maximum intensity projection (MIP; ITV_MIP), unions of the GTVs from selected multiple phases ITV2 (0% and 50% phases), ITV3 (ITV2 plus 80%), and ITV4 (ITV3 plus 60%), as well as the volumes expanded from ITV2 and ITV3 with a uniform margin. These ITVs were compared to ITV10 (the union of the GTVs for all 10 phases) and the differences were measured with the overlap ratio (OR) and relative volume ratio (RVR) relative to ITV10 (ITVx/ITV10).
RESULTS: For all patients studied, the average GTV from a single phase was 84.9% of ITV10. The average ORs were 91.2%, 91.3%, 94.5%, and 96.4% for ITV_MIP, ITV2, ITV3, and ITV4, respectively. Low ORs were associated with irregular breathing patterns. ITV3s plus 1 mm uniform margins (ITV3+1) led to an average OR of 98.1% and an average RVR of 106.4%.
CONCLUSIONS: The ITV generated directly from MIP underestimates the range of the respiration motion for esophageal cancer. The ITV generated from 3 phases (ITV3) may be used for regular breathers, whereas the ITV generated from 4 phases (ITV4) or ITV3 plus a 1-mm uniform margin may be applied for irregular breathers.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25015201     DOI: 10.1016/j.ijrobp.2014.05.015

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

1.  Optimizing geometric accuracy of four-dimensional CT scans acquired using the wall- and couch-mounted Varian® Real-time Position Management™ camera systems.

Authors:  B F O'Connell; D M Irvine; A J Cole; G G Hanna; C K McGarry
Journal:  Br J Radiol       Date:  2014-12-03       Impact factor: 3.039

2.  Esophageal motion characteristics in thoracic esophageal cancer: Impact of clinical stage T4 versus stages T1-T3.

Authors:  Yuta Kobayashi; Miyako Myojin; Shinichi Shimizu; Masao Hosokawa
Journal:  Adv Radiat Oncol       Date:  2016-08-23

3.  Reliability of ITV approach to varying treatment fraction time: a retrospective analysis based on 2D cine MR images.

Authors:  Davide Cusumano; Jennifer Dhont; Luca Boldrini; Giuditta Chiloiro; Angela Romano; Claudio Votta; Silvia Longo; Lorenzo Placidi; Luigi Azario; Marco De Spirito; Dirk Verellen; Vincenzo Valentini
Journal:  Radiat Oncol       Date:  2020-06-12       Impact factor: 3.481

4.  A comparative study of the normal oesophageal wall thickness based on 3-dimensional, 4-dimensional, and cone beam computed tomography.

Authors:  Chao Yue Hu; Yan Kang Li; Jian Bin Li; Jin Zhi Wang; Qian Shao; Wei Wang; Yan Luan Guo; Min Xu; Wen Wu Li
Journal:  Medicine (Baltimore)       Date:  2020-11-06       Impact factor: 1.817

  4 in total