Literature DB >> 2501462

The apnea test for the determination of brain death.

E C Benzel1, C D Gross, T A Hadden, L Kesterson, M D Landreneau.   

Abstract

By conventional criteria, an apneic patient's PaCO2 must be greater than 60 mm Hg before apnea can be attributed to brain death. The rate of a PaCO2 increase in the apneic patient traditionally has been thought to be in the range of 3 mm Hg/min. In order to assess the validity of these data and the validity of the "apnea test" for determination of brain death, the results of this test were reviewed in 20 patients. In all patients, arterial blood samples were drawn for blood gas measurements every 2 minutes following the cessation of volume ventilation (with an oxygen cannula at 6 liters O2/min passed into the tracheobronchial tree). The rate of PaCO2 increase was noted to be very erratic. The average rate of rise was 3.7 +/- 2.3 mm Hg/min (+/- standard deviation). This, however, varied from 0.5 to 10.5 mm Hg/min and was not predictable from the variables evaluated. The rate of PaCO2 increase was noted to decline throughout the duration of the test. This ranged from 3.9 +/- 1.2 mm Hg/min (for patients with baseline PaCO2 less than or equal to 30 mm Hg) and 4.5 +/- 1.9 mm Hg/min (for patients with baseline PaCO2 greater than or equal to 30 mm Hg) in the first 4 minutes of the test to an average of 0.92 mm Hg/min for patients with test lasted longer than 12 minutes. These unpredictable results might be related to CO2 washout, atelectasis, cardiac ventilations, or other yet-undefined parameters. The nonlinear relationship between rate of PaCO2 increase and time following onset of apnea resulted in the test being prolonged in several patients. In these patients, the PaCO2 approached 60 mm Hg in an asymptotic fashion. These lengthy tests could have been avoided by utilizing a standardized apnea test with a baseline PaCO2 of 40 mm Hg or greater. The observation that a high baseline PaCO2 greatly augments the efficiency and safety of the test allows criteria that have previously been based on conjecture to be documented and applied clinically. A standardized apnea test, utilizing these principles, may satisfy many of the criticisms regarding brain-death testing that have been raised by neurologists, neurosurgeons, and transplant surgeons.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2501462     DOI: 10.3171/jns.1989.71.2.0191

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

Review 1.  Drugs and brain death.

Authors:  M Kennedy; N Kiloh
Journal:  Drug Saf       Date:  1996-03       Impact factor: 5.606

Review 2.  [Apnea test for assessment of brain death under extracorporeal life support].

Authors:  S Winter; H V Groesdonk; M Beiderlinden
Journal:  Med Klin Intensivmed Notfmed       Date:  2017-04-25       Impact factor: 0.840

3.  The apnea test for brain death determination: an alternative approach.

Authors:  Michael D Sharpe; G Bryan Young; Chris Harris
Journal:  Neurocrit Care       Date:  2004       Impact factor: 3.210

4.  Reversibility of severe brain stem dysfunction in children.

Authors:  A Ammar; A Awada; I al-Luwami
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216

5.  Apnea testing in suspected brain dead children--physiological and mathematical modelling.

Authors:  G Paret; Z Barzilay
Journal:  Intensive Care Med       Date:  1995-03       Impact factor: 17.440

6.  Prolonged duration of apnea test during brain death examination in a case of intraparenchymal hemorrhage.

Authors:  Premkumar Nattanmai; Christopher R Newey; Ishpreet Singh; Keerthivaas Premkumar
Journal:  SAGE Open Med Case Rep       Date:  2017-06-22

7.  The usefulness of end-tidal carbon dioxide monitoring during apnea test in brain-dead patients.

Authors:  Ha Yeon Kim; Gaab-Soo Kim; Young Hee Shin; So Ra Cha
Journal:  Korean J Anesthesiol       Date:  2014-09-24

Review 8.  Apnea Testing for the Determination of Brain Death: A Systematic Scoping Review.

Authors:  Katharina M Busl; Ariane Lewis; Panayiotis N Varelas
Journal:  Neurocrit Care       Date:  2021-04       Impact factor: 3.532