Peri-strut low-intensity areas in optical coherence tomography correlate with peri-strut inflammation and neointimal proliferation: an in-vivo correlation study in the familial hypercholesterolemic coronary swine model of in-stent restenosis.

Armando Tellez1, Maxwell E Afari, Piotr P Buszman, Paul Seifert, Yanping Cheng, Krzysztof Milewski, Jennifer C McGregor, Javier A Garza, Mary B Roberts, Geng Hua Yi, Greg L Kaluza, Juan F Granada.   

Abstract

BACKGROUND: Peri-strut low-intensity area (PLI) is a common imaging finding during the evaluation of in-stent neointima using optical coherence tomography (OCT). We aimed to determine the biological significance of PLI by comparing in-vivo OCT images with the corresponding histological sections obtained from the familial hypercholesterolemic swine model of coronary stenosis.
METHODS: A total of 26 coronary vessels of nine familial hypercholesterolemic swine were injured with 30% balloon overstretch and then immediately followed by everolimus eluting or bare metal stent placement at 20% overstretch. At 30 days, all stented vessels were subjected to in-vivo OCT analysis and were harvested for histological evaluation. For OCT analysis, stent cross-sections (three per stent) were categorized into presence (PLI+) or absence (PLI-) of PLI. In histology, inflammation and fibrin deposition were scored semiquantitatively from 0 (none) to 3 (severe).
RESULTS: PLI was found in 64.9% of stent sections. Peri-strut inflammation was more frequently observed in OCT sections PLI (+) compared with PLI (-) (56.0 vs. 7.4%, P=0.01). In contrast, peri-strut fibrin deposits was similar in both groups (PLI+=58.0% vs. PLI-=59.3%, P=0.94). Histological neointimal thickness was significantly higher in PLI (+) sections (mean±SE: 0.68±0.06 vs. 0.34±0.02 mm; P<0.01), yielding a higher percent area stenosis compared with PLI (-) (mean±SE: 59.0±4.4 vs. 34.1±2.2%, P<0.01). The PLI diagnostic sensitivity and specificity for inflammation were 80 and 76.1%, respectively (>56% PLI, area under the curve=0.86, P<0.01), whereas for fibrin deposition, the sensitivity and specificity were 42.2 and 76.1%, respectively (area under the curve=0.56, P=NS). Area under the receiver operating characteristic curve was significantly higher for identifying inflammation than fibrin (0.86 vs. 0.56, P<0.01). The severity of PLI correlated with the neointimal thickness when assessed by OCT (R=0.79, P<0.001).
CONCLUSION: The presence of PLI in OCT correlates with neointimal thickness and appears to have a diagnostic value in the recognition of peri-strut inflammation, therefore possibly serving as a surrogate for in-vivo assessment of stent efficacy.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25013949     DOI: 10.1097/MCA.0000000000000134

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  6 in total

1.  Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes.

Authors:  Ryota Kakizaki; Yoshiyasu Minami; Masahiro Katamine; Aritomo Katsura; Yusuke Muramatsu; Takuya Hashimoto; Kentaro Meguro; Takao Shimohama; Junya Ako
Journal:  Cardiovasc Diabetol       Date:  2020-10-01       Impact factor: 9.951

2.  Bioresorbable scaffold -fourth revolution or failed revolution: Is low scaffold strut thickness the wrong target?

Authors:  Sundeep Mishra
Journal:  Indian Heart J       Date:  2017-10-06

3.  Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report.

Authors:  Takahiro Jimba; Takehiro Hashikata; Masashiro Matsushita; Masao Yamasaki
Journal:  Eur Heart J Case Rep       Date:  2020-02-04

Review 4.  OCT demonstrating neoatherosclerosis as part of the continuous process of coronary artery disease.

Authors:  B-C Zhang; A Karanasos; E Regar
Journal:  Herz       Date:  2015-09       Impact factor: 1.443

Review 5.  Modelling the Impact of Atherosclerosis on Drug Release and Distribution from Coronary Stents.

Authors:  C M McKittrick; S Kennedy; K G Oldroyd; S McGinty; C McCormick
Journal:  Ann Biomed Eng       Date:  2015-09-18       Impact factor: 3.934

6.  Clinical Characteristics and Prognosis of Peri-strut Low-intensity Area Detected by Optical Coherence Tomography.

Authors:  De-Wei Wu; Meng-Yue Yu; Hai-Yang Gao; Zhe He; Jing Yao; Cheng Ding; Bo Xu; Li Zhang; Fei Song; Qing-Rong Liu; Yong-Jian Wu
Journal:  Chin Med J (Engl)       Date:  2015-12-05       Impact factor: 2.628

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.