A simple method for detecting vitrectomy infusion line position in hazy media, in case of poor visualization.

Nasser Shoeibi1, Mohammad-Rea Ansari-Astaneh.   

Abstract

PURPOSE: To introduce a simple and practical method for detecting vitrectomy infusion line position in a hazy media.
METHODS: The position of the infusion cannula was evaluated before and during vitrectomy in 17 eyes of 17 patients with hazy media. This procedure was performed by using the light pipe inserted partially into the cannula and determining the color of transmitted light into the vitreous cavity. Dark red or brownish color was considered as suprachoroidal placement and bright whitish color as the correct position of the cannula tip.
RESULTS: In 13 patients, the position of the cannula was considered as a precise position by using the aforementioned method at the beginning of the operation, and vitrectomy was performed without any infusion line-related complications. In two cases, the incorrect placement of the infusion cannula was confirmed with this technique, and the cannula was reinserted and repositioned. In two cases, secondary slippage of the cannula in suprachoroidal space was detected by using this method during vitrectomy, and another cannula was tried in another position.
CONCLUSION: Using the color of light pipe inserted partially into the cannula is a safe and simple method for evaluating the position of the infusion line in the eye.

Entities:  

Mesh:

Year:  2014        PMID: 25011023     DOI: 10.1097/IAE.0000000000000257

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  1 in total

1.  The use of air from the infusion line to confirm infusion tip positioning in vitreous surgery for eyes with media opacities.