Literature DB >> 25010876

Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions.

Hazem Tamim, Henrik Skjerven, Anders Ekfeldt, Hans Jacob Rønold.   

Abstract

PURPOSE: The aim of this in vivo study was to evaluate the accuracy of metal-ceramic crowns fabricated using computer-aided design/computer-assisted manufacturing (CAD/CAM) in conjunction with intraoral digital impressions.
MATERIALS AND METHODS: Fifty patients in a general practice participated in the study. Patients were provided with crowns fabricated from digital impressions taken with an intraoral chairside scanner. Prior to crown insertion, the marginal integrity, esthetics, and occlusal and articulation contacts were evaluated using California Dental Association (CDA) criteria. The precementation space of the crowns was evaluated with the replica technique.
RESULTS: No adjustments were needed for any of the interproximal contact points. Adjustments of occlusion and articulation contacts were needed in 20% of the restorations. Clinical evaluation of the marginal integrity showed satisfactory results according to the CDA criteria. The 50 silicone replicas showed a median precementation space of 46 μm at the marginal measurement location, 94 μm at the midaxial location, and 185 μm at the centro-occlusal location.
CONCLUSIONS: The precementation spaces of the crowns were within the acceptable range for CAD/CAM restorations.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25010876     DOI: 10.11607/ijp.3607

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  11 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study.

Authors:  Matthias Rödiger; Arthur Heinitz; Ralf Bürgers; Sven Rinke
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

3.  Impression evaluation and laboratory use for single-unit crowns: Findings from The National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; Mark S Litaker; Ashley J George; Scott Durand; Sepideh Malekpour; Don G Marshall; Cyril Meyerowitz; Lauren Carter; Valeria V Gordan; Gregg H Gilbert
Journal:  J Am Dent Assoc       Date:  2017-08-16       Impact factor: 3.634

4.  Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions.

Authors:  Kazuhiko Ueda; Florian Beuer; Michael Stimmelmayr; Kurt Erdelt; Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2015-06-30       Impact factor: 3.573

5.  In vitro Comparison of the Accuracy (Precision and Trueness) of Seven Dental Scanners.

Authors:  Fariborz Vafaee; Farnaz Firouz; Mahsa Mohajeri; Reza Hashemi; Somayeh Ghorbani Gholiabad
Journal:  J Dent (Shiraz)       Date:  2021-03

Review 6.  Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature.

Authors:  Kusai Baroudi; Shukran Nasser Ibraheem
Journal:  J Int Oral Health       Date:  2015-04

7.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

Review 8.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

9.  Fabrication of Zirconia-Reinforced Lithium Silicate Ceramic Restorations Using a Complete Digital Workflow.

Authors:  Sven Rinke; Matthias Rödiger; Dirk Ziebolz; Anne-Kathrin Schmidt
Journal:  Case Rep Dent       Date:  2015-10-05

10.  The Prosthetic Workflow in the Digital Era.

Authors:  Lidia Tordiglione; Michele De Franco; Giovanni Bosetti
Journal:  Int J Dent       Date:  2016-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.