Literature DB >> 25004940

Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

M Jiránek1.   

Abstract

Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, which is twice greater than when additionally applied radon-proof insulation is used. The efficiency is mainly influenced by the vertical profile of the soil permeability and by the air-tightness of floors resting on the soil. Higher efficiency was found for houses with greater air-tightness of the floors and with a sub-floor layer with permeability higher than the permeability of the subsoil.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Mesh:

Substances:

Year:  2014        PMID: 25004940     DOI: 10.1093/rpd/ncu219

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Research on Best Solution for Improving Indoor Air Quality and Reducing Energy Consumption in a High-Risk Radon Dwelling from Romania.

Authors:  Ion-Costinel Mareș; Tiberiu Catalina; Marian-Andrei Istrate; Alexandra Cucoș; Tiberius Dicu; Betty Denissa Burghele; Kinga Hening; Lelia Letitia Popescu; Razvan Stefan Popescu
Journal:  Int J Environ Res Public Health       Date:  2021-11-26       Impact factor: 3.390