Literature DB >> 25004939

The effect of dose and water treatment on EPR signals in irradiated fingernails.

A Marciniak1, B Ciesielski2, A Prawdzik-Dampc3.   

Abstract

Fast and precise retrospective dosimetry is crucial in making decisions about medical procedures and safety measures in radiation accidents. Electron paramagnetic resonance (EPR) spectroscopy has a potential as one of available biodosimetry methods for use in victims of such incidents. In this study, authors present the findings on EPR dosimetry in fingernails. Authors describe changes of EPR signals in unirradiated and irradiated nails in time after cutting and the effect of water on the mechanically induced and radiation-induced EPR signals measured ex vivo in the fingernails. The effect of dose on amplitude of the EPR signal was measured in nails that were soaked for 10 min in water after their irradiation. The obtained dose-response curves, which reflect changes in concentration of the radiation-induced RIS5 radicals, reach their maximum for doses of 40-60 Gy.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25004939     DOI: 10.1093/rpd/ncu207

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Dielectric-Backed Aperture Resonators for X-Band in vivo EPR Nail Dosimetry.

Authors:  Oleg Grinberg; Jason W Sidabras; Dmitriy S Tipikin; Vladimir Krymov; Michael Mariani; Matthew M Feldman; Maciej M Kmiec; Sergey V Petryakov; Spencer Brugger; Brandon Carr; Wilson Schreiber; Steven G Swarts; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-13       Impact factor: 0.972

2.  Emergency EPR dosimetry technique using vacuum-stored dry nails.

Authors:  S Sholom; S W S McKeever
Journal:  Radiat Meas       Date:  2016-02-06       Impact factor: 1.898

3.  Stability of X-band EPR signals from fingernails under vacuum storage.

Authors:  Sergey Sholom; Stephen McKeever
Journal:  Radiat Phys Chem Oxf Engl 1993       Date:  2017-06-12       Impact factor: 2.858

4.  Effects of water on fingernail electron paramagnetic resonance dosimetry.

Authors:  Tengda Zhang; Zhixin Zhao; Haiying Zhang; Hezheng Zhai; Shuzhou Ruan; Ling Jiao; Wenyi Zhang
Journal:  J Radiat Res       Date:  2016-06-24       Impact factor: 2.724

5.  Behavior of the electron spin resonance signals in X-ray irradiated human fingernails for the establishment of a dose reconstruction procedure.

Authors:  Seiko Hirota; Chryzel Angelica B Gonzales; Hiroshi Yasuda
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

  5 in total