Literature DB >> 25002387

Prosthesis-patient mismatch causes a significantly increased risk of operative mortality in aortic valve replacement.

Khan Muhammad Shahzeb1, Bawany Faizan Imran1, Khan Asadullah2, Hussain Mehwish1.   

Abstract

BACKGROUND: Small aortic prosthesis can lead to prosthesis-patient mismatch (PPM). Implanting such small prosthesis remains a controversial issue. This study was done to investigate whether or not PPM causes an increased operative mortality in aortic valve replacement (AVR).
METHODS: Two-hundred-two consecutive patients undergoing primary AVR in a tertiary hospital were included. The sample was grouped according to the aortic valve prosthesis size: ≤21 mm (small) and >21 mm (standard). The effect of variables on outcomes was determined by univariate and multivariable regression analyses.
RESULTS: PPM was found significantly more among patients with AVR ≤ 21 mm (P < 0.0001). Moreover, the likelihood of mortality also was significantly higher in these patients (P < 0.0001). Univariate analysis demonstrated small prosthesis size, urgent operation, PPM, female gender, and NYHA Class IV as significant predictors of mortality. Multivariate regression identified female gender, PPM, and urgent operation as the key independent predictors of mortality.
CONCLUSION: PPM and female gender are significant predictors of mortality. Care should be taken to prevent PPM by implanting larger prosthesis especially in females.

Entities:  

Mesh:

Year:  2014        PMID: 25002387     DOI: 10.1532/HSF98.2013304

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  2 in total

1.  Physiological rules for the heart, lungs and other pressure-based organs.

Authors:  Aaron R Casha; Liberato Camilleri; Alexander Manché; Ruben Gatt; Marilyn Gauci; Marie-Therese Camilleri-Podesta; Joseph N Grima; Marco Scarci; Stanley Chetcuti
Journal:  J Thorac Dis       Date:  2017-10       Impact factor: 2.895

2.  Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients' Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis.

Authors:  Alireza Alizadeh-Ghavidel; Rasoul Azarfarin; Azin Alizadehasl; Ali Sadeghpour-Tabaei; Ziae Totonchi
Journal:  Res Cardiovasc Med       Date:  2016-03-05
  2 in total